ArticleMicromachines2018
A Plantar Pressure Sensing System with Balancing Sensitivity Based on Tailored MWCNTs/PDMS Composites.
Article in Micromachines, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 15 citations in OpenAlex.
- Recent Innovations in Footwear and the Role of Smart Footwear in Healthcare-A Survey.Sensors (Basel, Switzerland) · 2024Review
- Gait Pattern Analysis: Integration of a Highly Sensitive Flexible Pressure Sensor on a Wireless Instrumented Insole.Sensors (Basel, Switzerland) · 2024Article
- Smart Shoe Insole Based on Polydimethylsiloxane Composite Capacitive Sensors.Sensors (Basel, Switzerland) · 2023Article
- A Focused Review on the Flexible Wearable Sensors for Sports: From Kinematics to Physiologies.Micromachines · 2022Review
- Flexible Ultra-Thin Nanocomposite Based Piezoresistive Pressure Sensors for Foot Pressure Distribution Measurement.Sensors (Basel, Switzerland) · 2021Article
- Flexible Piezoresistive Tactile Sensor Based on Polymeric Nanocomposites with Grid-Type Microstructure.Micromachines · 2021Article
- Printed and Flexible Capacitive Pressure Sensor with Carbon Nanotubes based Composite Dielectric Layer.Micromachines · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
This paper presents a flexible plantar pressure sensor with a simple structure and easy accessibility, suitable for everyday use. In this study, the design, fabrication, and characteristics of both the composite and the sensor were involved. By using the solution method, the piezoresistive composite was fabricated by uniform dispersion of multiwall carbon nanotubes (MWCNTs) into the polydimethylsiloxane (PDMS) matrix. The proposed sensor consists of eight sensing elements with a laminated structure. The upper layer is a sensing layer made of the piezoresistive composite, and the lower layer is a flexible printed circuit-board working as electrodes. A particular design of sensing elements was carried out by using different doping concentrations according to arrangement positions under the feet to obtain balancing sensitivity. A signal processing system to convert the variable resistance signal into voltages by the current-to-voltage method was designed. Experimental results prove that the designed sensor shows a repeatable response with a sensitivity of 11.5 mV/kPa within the range of 265 kPa. Also, an actual application verifies that the designed plantar pressure sensor can measure the pressure under the foot and can be used for gait detection and disease diagnosis purposes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.