Evidence map›Paper›PMID 30424103›Full record

ArticleMicromachines2018

Stretchable Tattoo-Like Heater with On-Site Temperature Feedback Control.

Andrew Stier, Eshan Halekote, Andrew Mark, Shutao Qiao, Shixuan Yang, Kenneth Diller, Nanshu Lu

Abstract read
In one paragraph

Article in Micromachines, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Review
  2. Research on Flexible Sensors for Wearable Devices: A Review.Nanomaterials (Basel, Switzerland) · 2025
    Review
  3. Miniaturized, portable gustation interfaces for VR/AR/MR.Proceedings of the National Academy of Sciences of the United States of America · 2024
    Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Andrew StierDepartment of Electrical and Computer Engineering, University of Texas at Austin, Austin, TX 78712, USA. andrewcstier@gmail.com.
Eshan HalekoteDepartment of Electrical and Computer Engineering, University of Texas at Austin, Austin, TX 78712, USA. ehalekote@gmail.com.
Andrew MarkDepartment of Electrical and Computer Engineering, University of Texas at Austin, Austin, TX 78712, USA. andrewemark@gmail.com.
Shutao QiaoCenter for Mechanics of Solids, Structures and Materials, Department of Aerospace Engineering and Engineering Mechanics, University of Texas at Austin, Austin, TX 78712, USA. shutao2011@gmail.com.
Shixuan YangCenter for Mechanics of Solids, Structures and Materials, Department of Aerospace Engineering and Engineering Mechanics, University of Texas at Austin, Austin, TX 78712, USA. rock002008@gmail.com.
Kenneth DillerDepartment of Biomedical Engineering, University of Texas at Austin, Austin, TX 78712, USA. kdiller@mail.utexas.edu.
Nanshu LuDepartment of Electrical and Computer Engineering, University of Texas at Austin, Austin, TX 78712, USA. nanshulu@utexas.edu.

Funding

National Science Foundation Grant BET1250659Office of Naval Research Young Investigator Award N00014-16-1-2044
6 · The paper itself

Abstract

Wearable tissue heaters can play many important roles in the medical field. They may be used for heat therapy, perioperative warming and controlled transdermal drug delivery, among other applications. State-of-the-art heaters are too bulky, rigid, or difficult to control to be able to maintain long-term wearability and safety. Recently, there has been progress in the development of stretchable heaters that may be attached directly to the skin surface, but they often use expensive materials or processes and take significant time to fabricate. Moreover, they lack continuously active, on-site, unobstructive temperature feedback control, which is critical for accommodating the dynamic temperatures required for most medical applications. We have developed, fabricated and tested a cost-effective, large area, ultra-thin and ultra-soft tattoo-like heater that has autonomous proportional-integral-derivative (PID) temperature control. The device comprises a stretchable aluminum heater and a stretchable gold resistance temperature detector (RTD) on a soft medical tape as fabricated using the cost and time effective "cut-and-paste" method. It can be noninvasively laminated onto human skin and can follow skin deformation during flexure without imposing any constraint. We demonstrate the device's ability to maintain a target temperature typical of medical uses over extended durations of time and to accurately adjust to a new set point in process. The cost of the device is low enough to justify disposable use.

Indexed as

epidermal electronicsfeedback controltemperature sensorwearable heater

Identifiers

PMID30424103
PMCPMC6187738

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.