Evidence map›Paper›PMID 30424026›Full record

ArticleMicromachines2018

Electrowetting Using a Microfluidic Kelvin Water Dropper.

Elias Yazdanshenas, Qiang Tang, Xiaoyu Zhang

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 54% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 2 countries.

Elias YazdanshenasDepartment of Mechanical & Aerospace Engineering, Old Dominion University, Norfolk, VA 23529, USA. eyazd001@odu.edu.
Qiang TangDepartment of Mechanical & Aerospace Engineering, Old Dominion University, Norfolk, VA 23529, USA. tangqiang102@126.com.
Xiaoyu ZhangDepartment of Mechanical & Aerospace Engineering, Old Dominion University, Norfolk, VA 23529, USA. x1zhang@odu.edu.
Old Dominion University · US

Funding

National Science Foundation 1560194
6 · The paper itself

Abstract

The Kelvin water dropper is an electrostatic generator that can generate high voltage electricity through water dripping. A conventional Kelvin water dropper converts the gravitational potential energy of water into electricity. Due to its low current output, Kelvin water droppers can only be used in limited cases that demand high voltage. In the present study, microfluidic Kelvin water droppers (MKWDs) were built in house to demonstrate a low-cost but accurately controlled miniature device for high voltage generation. The performance of the MKWDs was characterized using different channel diameters and flow rates. The best performed MKWD was then used to conduct experiments of the electrowetting of liquid on dielectric surfaces. Electrowetting is a process that has been widely used in manipulating the wetting properties of a surface using an external electric field. Usually electrowetting requires an expensive DC power supply that outputs high voltage. However, in this research, it was demonstrated that electrowetting can be conducted by simply using an MKWD. Additionally, an analytic model was developed to simulate the electrowetting process. Finally, the model's ability to well predict the liquid deformation during electrowetting using MKWDs was validated.

Indexed as

COMSOLelectrowettinghigh voltagemicrofluidic Kelvin water dropper

Identifiers

PMID30424026
PMCPMC6187503
OpenAlexW2793562044

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.