Evidence map›Paper›PMID 30423988›Full record

ArticleSensors (Basel, Switzerland)2018

A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine.

Paul C-P Chao, Pei-Yu Chiang, Yung-Hua Kao, Tse-Yi Tu, Chih-Yu Yang, Der-Cherng Tarng, Chin-Long Wey

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Paul C-P ChaoInstitute of Electrical and Control Engineering, National Chiao Tung University, Hsinchu 300, Taiwan. pchao@mail.nctu.edu.tw.ORCID 0000-0003-2835-9157
Pei-Yu ChiangInstitute of Electrical and Control Engineering, National Chiao Tung University, Hsinchu 300, Taiwan. mekool.eed00@g2.nctu.edu.tw.ORCID 0000-0002-1456-1138
Yung-Hua KaoInstitute of Electrical and Control Engineering, National Chiao Tung University, Hsinchu 300, Taiwan. yunghwa.kao@gmail.com.
Tse-Yi TuInstitute of Electrical and Control Engineering, National Chiao Tung University, Hsinchu 300, Taiwan. tu.tseyi@gmail.com.
Chih-Yu YangDivision of Nephrology in Taipei Veterans General Hospital, Taipei 112, Taiwan. cyyang3@vghtpe.gov.tw.
Der-Cherng TarngDivision of Nephrology in Taipei Veterans General Hospital, Taipei 112, Taiwan. dctarng@vghtpe.gov.tw.ORCID 0000-0001-9017-2081
Chin-Long WeyInstitute of Electrical and Control Engineering, National Chiao Tung University, Hsinchu 300, Taiwan. clwey@cc.nctu.edu.tw.
National Yang Ming Chiao Tung University · TWTaipei Veterans General Hospital · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A portable, wireless photoplethysomography (PPG) sensor for assessing arteriovenous fistula (AVF) by using class-weighted support vector machines (SVM) was presented in this study. Nowadays, in hospital, AVF are assessed by ultrasound Doppler machines, which are bulky, expensive, complicated-to-operate, and time-consuming. In this study, new PPG sensors were proposed and developed successfully to provide portable and inexpensive solutions for AVF assessments. To develop the sensor, at first, by combining the dimensionless number analysis and the optical Beer Lambert's law, five input features were derived for the SVM classifier. In the next step, to increase the signal-noise ratio (SNR) of PPG signals, the front-end readout circuitries were designed to fully use the dynamic range of analog-digital converter (ADC) by controlling the circuitries gain and the light intensity of light emitted diode (LED). Digital signal processing algorithms were proposed next to check and fix signal anomalies. Finally, the class-weighted SVM classifiers employed five different kernel functions to assess AVF quality. The assessment results were provided to doctors for diagonosis and detemining ensuing proper treatments. The experimental results showed that the proposed PPG sensors successfully achieved an accuracy of 89.11% in assessing health of AVF and with a type II error of only 9.59%.

Indexed as

AlgorithmsArteriovenous FistulaBiosensing TechniquesHospitalsHumansOutcome Assessment, Health CarePhotoplethysmographySignal Processing, Computer-AssistedSignal-To-Noise RatioSupport Vector MachineUltrasonographyWireless Technologyarteriovenous fistula (AVF)photoplethysmography (PPG) sensorsupport vector machine (SVM)

Identifiers

PMID30423988
PMCPMC6263509
OpenAlexW2901443959

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.