Evidence map›Paper›PMID 30421451›Full record

ArticleMagnetic resonance in medicine2019

Correcting image blur in spiral, retraced in/out (RIO) acquisitions using a maximized energy objective.

Steven P Allen, Xue Feng, Samuel W Fielden, Craig H Meyer

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. SPRING-RIO TSE: 2D TMagnetic resonance in medicine · 2022
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Steven P AllenDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia.
Xue FengDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia.
Samuel W FieldenDepartment of Imaging Science and Innovation, Geisinger, Danville, Pennsylvania.
Craig H MeyerDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia.

Funding

BASIC CARDIOVASCULAR RESEARCH TRAINING GRANTT32HL007284 · NHLBI · UNIVERSITY OF VIRGINIA CHARLOTTESVILLE · PI Brant E Isakson, Gary K Owens · 1985 to 2026
$19.6M
Motion-Robust Methods for Rapid Pediatric MRI without SedationR21EB022309 · NIBIB · UNIVERSITY OF VIRGINIA · PI MEYER, CRAIG H · 2016 to 2018
$539k
Focused Ultrasound FoundationNHLBI NIH HHS T32 HL 007284NHLBI NIH HHS T32 HL007284NIBIB NIH HHS R21 EB022309Siemens Medical Solutions
6 · The paper itself

Abstract

purposeImages acquired with spiral k-space trajectories can suffer from off-resonance image blur. Previous work showed that averaging 2 images acquired with a retraced, in/out (RIO) trajectory self-corrects image blur so long as off-resonant spins accrue less than 1 half-cycle of relative phase over the readout. Practical scenarios frequently exceed this threshold. Here, we derive and characterize a more-robust off-resonance image blur correction method for RIO acquisitions.

methodsPhantom and human volunteer data were acquired using a RIO trajectory with readout durations ranging from 4 to 60 ms. The resulting images were deblurred using 3 candidate methods: conventional linear correction of the component images; semiautomatic deblurring of the component images using an established minimized phase objective function; and semiautomatic deblurring of the average of the component images using a maximized energy objective function, derived below. Deblurring errors were estimated relative to images acquired with 4 ms readouts.

resultsAll 3 methods converged to similar solutions in cases where less than 2 and 4 cycles of phase accrued over the readout in in vivo and phantom images, respectively (<13 ms readout at 3T). Above this threshold, the linear and minimized phase methods introduced several errors. The maximized energy function provided accurate deblurring so long as less than 6 and 10 cycles of phase accrued over the readout in in vivo and phantom images, respectively (<34 ms readout at 3T).

conclusionThe maximized energy objective function can accurately deblur RIO acquisitions over a wide spectrum of off resonance frequencies.

Indexed as

Magnetic Resonance ImagingAlgorithmsArtifactsBrainComputer SimulationHumansImage EnhancementImage Processing, Computer-AssistedModels, StatisticalPattern Recognition, AutomatedPhantoms, Imagingdeblurringdouble encodingMRIoff-resonance correctionretraced in/out spiralsspiral

Identifiers

PMID30421451
PMCPMC6859899

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.