Development of 3D patient-based super-resolution digital breast phantoms using machine learning.

Marco Caballo, Christian Fedon, Luca Brombal, Ritse Mann, Renata Longo, Ioannis Sechopoulos

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Marco CaballoDepartment of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, Netherlands.ORCID 0000-0002-3700-2785
Christian FedonDepartment of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, Netherlands.ORCID 0000-0002-5998-453X
Luca BrombalIstituto Nazionale di Fisica Nucleare (INFN), sezione di Trieste, 34127 Trieste, Italy.ORCID 0000-0002-4009-8191
Ritse MannDepartment of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, Netherlands.
Renata LongoIstituto Nazionale di Fisica Nucleare (INFN), sezione di Trieste, 34127 Trieste, Italy.
Ioannis SechopoulosDepartment of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, Netherlands.
Radboud University Nijmegen · NLUniversity of Trieste · IT

Funding

Image Quality Improvement and Performance Assessment of Dedicated Breast CTR01CA181171 · NCI · STICHTING RADBOUD UNIVERSITAIR MEDISCH CENTRUM I.O. · PI SECHOPOULOS, IOANNIS · 2015 to 2020
$1.1M
NCI NIH HHS R01 CA181171
6 · The paper itself

Abstract

Digital phantoms are important tools for optimization and evaluation of x-ray imaging systems, and should ideally reflect the 3D structure of human anatomy and its potential variability. In addition, they need to include a good level of detail at a high enough spatial resolution to accurately model the continuous nature of the human anatomy. A pipeline to increase the spatial resolution of patient-based digital breast phantoms that can be used for computer simulations of breast imaging is proposed. Given a tomographic breast image of finite resolution, the proposed methods can generate a phantom and increase its resolution at will, not only simply through super-sampling, but also by generating additional random glandular details to account for glandular edges and strands to compensate for those that may have not been detected in the original image due to the limited spatial resolution of the imaging system used. The proposed algorithms use supervised learning to predict the loss in glandularity due to limited resolution, and then to realistically recover this loss by learning the mapping between low and high resolution images. They were trained on high-resolution synchrotron images (detector pixel size 60 μm) reconstructed at seven voxel dimensions (60 μm-480 μm), and applied to patient images acquired with a clinical breast CT system (detector pixel size 194 μm) to generate super-resolution phantoms (voxel sizes 68 μm). Several evaluations were made to assess the appropriateness of the developed methods, both with the synchrotron (relative prediction error 0.010  ±  0.004, recovering accuracy 0.95  ±  0.04), and with the clinical images (average glandularity error at 194 μm: 0.15%  ±  0.12%). Finally, a breast radiologist assessed the realism of the developed phantoms by blindly comparing original and phantom images, resulting in not being able to distinguish the real from the phantom images. In conclusion, the proposed method can generate super-resolution phantoms from tomographic breast patient images that can be used for future computer simulations for optimization of new breast imaging technologies.

Indexed as

Machine LearningBreastFemaleHumansImaging, Three-DimensionalPhantoms, ImagingPrecision MedicineTomography, X-Ray Computed

Identifiers

PMID30418943
PMCPMC6419955
OpenAlexW2897979641

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.