Evidence map›Paper›PMID 30416781›Full record

ArticleJournal of thoracic disease2018

Suturing of the laser resection area is recommended over a depth of 2 cm in an experimental porcine lung model.

Andreas Kirschbaum, Thomas M Surowiec, Anika Pehl, Andreas Gockel, Detlef K Bartsch, Nikolas Mirow

Open access · hybridAbstract read
In one paragraph

Article in Journal of thoracic disease, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Advances and safe use of energy devices in lung cancer surgery.General thoracic and cardiovascular surgery · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Andreas KirschbaumDepartment of Visceral, Thoracic and Vascular Surgery, University Hospital Marburg, Marburg, Germany.
Thomas M SurowiecDepartment of Mathematics and Computer Science, University of Marburg, Marburg, Germany.
Anika PehlInstitute of Pathology, University Hospital Marburg, Marburg, Germany.
Andreas GockelDepartment of Anesthesiology and Intensive Care Medicine, University Hospital Marburg, Marburg, Germany.
Detlef K BartschDepartment of Visceral, Thoracic and Vascular Surgery, University Hospital Marburg, Marburg, Germany.
Nikolas MirowDepartment of Cardiac and Thoracic Vascular Surgery, University Hospital Marburg, Marburg, Germany.
Philipps University of Marburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLung metastases can be removed by an Nd:YAG laser to save lung parenchyma. At these sites, a coagulated lung surface remains. Airtightness was investigated in relation to the depth of resection on an

methodsFreshly slaughtered porcine double lung preparations were connected to a ventilator via a tube. Non-anatomical laser resections were performed with an 800 µm laser fiber and the Nd:YAG laser LIMAX

resultsUp to a resection depth of 1.5 cm, the ventilated resection surfaces were completely airtight regardless of the laser power. From a depth of resection of 1.5 cm, a mean air volume loss of 28.9±5.3 mL/respiratory cycle at 40 watts and of 26.4±5.8 mL at 60 watts was found. Additional surface coagulation did not significantly reduce the leakage rate. In contrast, suturing significantly reduced (P<0.0001) to 7.2±3.7 mL/ventilation (40 watts) and 6.0±3.4 mL/ventilation. At a resection depth of 2 cm, the leakage volume was 42.9±3.3 mL/respiratory cycle (40 watt) and 46.3±6.4 mL/respiratory cycle (60 watt). Additional surface coagulation failed to significantly reduce leakage volume, but suture closure provided airtightness.

conclusionsIn non-ventilated porcine lungs, Nd:YAG laser resection surfaces up to a resection depth of 1.5 cm are airtight after ventilation onset. From a depth of 1.5 cm, closure of resection surfaces by an additional suture is needed. Airtightness of resection surfaces was not increased by additional coagulation.

Indexed as

air leakageAirtightnesslaser fiberlung metastasesND:YAG laser non-anatomical laser resection

Identifiers

PMID30416781
PMCPMC6196183
OpenAlexW2892052988

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked