Evidence map›Paper›PMID 30416181›Full record

ArticleMagnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine2019

Signal Intensity of the Cerebrospinal Fluid after Intravenous Administration of Gadolinium-based Contrast Agents: Strong Contrast Enhancement around the Vein of Labbe.

Toshio Ohashi, Shinji Naganawa, Eriko Ogawa, Toshio Katagiri, Kayao Kuno

Open access · diamondAbstract read
In one paragraph

Article in Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed, 1 pooled it
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 1 synthesis or guideline pooled it, 22 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Review
  5. Contrast Enhancement of the Normal Infundibular Recess Using Heavily T2-weighted 3D FLAIR.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2022
    Article
  6. Article
  7. Article
  8. Distribution of Gadolinium-based Contrast Agent after Leaking into the Cerebrospinal Fluid: Comparison between the Cerebral Cisterns and the Lateral Ventricles.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2021
    Article
  9. Article
  10. Review
  11. Review
  12. Review
  13. Review
  14. Detection of IV-gadolinium Leakage from the Cortical Veins into the CSF Using MR Fingerprinting.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2020
    Article
  15. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Toshio OhashiDepartment of Radiology, Kamiiida Daiichi General Hospital.
Shinji NaganawaDepartment of Radiology, Nagoya University Graduate School of Medicine.
Eriko OgawaDepartment of Radiology, Kamiiida Daiichi General Hospital.
Toshio KatagiriDepartment of Radiology, Kamiiida Daiichi General Hospital.
Kayao KunoDepartment of Otorhinolaryngology, Kamiiida Daiichi General Hospital.
Kamiichi General Hospital · JPNagoya University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeSince the first report on the deposition of gadolinium in the brain parenchyma after repeated intravenous administrations of gadolinium-based contrast agent GBCA (IV-GBCA), the mechanisms of penetration and retention are still remaining a hot topic of discussion and a target of investigation. We routinely obtain endolymphatic hydrops (EH) images at 4 h after IV administration of a single dose (SD) of GBCA (IV-SD-GBCA) using heavily T MATERIALS AND

methodsIn 25 patients with a suspicion of EH, a magnetic resonance cisternography (MRC) and an hT

resultsThe SIR of the CSF-VL was significantly higher than that of the PVS (P = 0.008), the CSF-Amb (P = 0.021), and the CSF-SMCV (P = 0.023).

conclusionThe strong contrast enhancement of CSF space around the vein of Labbe was confirmed on hT

Indexed as

Administration, IntravenousAdultAgedBasal GangliaBrainCerebral VeinsCerebrospinal FluidContrast MediaEndolymphatic HydropsFemaleGadolinium DTPAHumansMagnetic Resonance ImagingMaleMiddle AgedSubarachnoid SpaceContrast MediaGadolinium DTPAcerebrospinal fluidgadoliniumglymphatic systemmagnetic resonance imagingvein

Identifiers

PMID30416181
PMCPMC6630048
OpenAlexW2900338570

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.