Evidence map›Paper›PMID 30414066›Full record

ArticleJournal of the American Society for Mass Spectrometry2019

Application of Group I Metal Adduction to the Separation of Steroids by Traveling Wave Ion Mobility Spectrometry.

Alana L Rister, Tiana L Martin, Eric D Dodds

Abstract read
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Article
  2. Structural Elucidation of Phosphatidylcholines via Radical-Directed Dissociation of [M + CuJournal of the American Society for Mass Spectrometry · 2025
    Article
  3. Rapid Annotation Strategy forJournal of the American Society for Mass Spectrometry · 2025
    Article
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Targeted glucocorticoid analysis using ion mobility-mass spectrometry (IM-MS).Journal of mass spectrometry and advances in the clinical lab · 2022
    Article
  12. Liquid chromatography-ion mobility spectrometry-mass spectrometry analysis of multiple classes of steroid hormone isomers in a mixture.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2020
    Article
  13. Article
  14. Article
  15. Imaging Isomers on a Biological Surface: A Review.Mass spectrometry (Tokyo, Japan) · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Alana L RisterDepartment of Chemistry, University of Nebraska - Lincoln, Lincoln, NE, 68588-0304, USA.ORCID http://orcid.org/0000-0002-7220-0728
Tiana L MartinDepartment of Chemistry, University of Nebraska - Lincoln, Lincoln, NE, 68588-0304, USA.ORCID http://orcid.org/0000-0003-3726-1215
Eric D DoddsDepartment of Chemistry, University of Nebraska - Lincoln, Lincoln, NE, 68588-0304, USA. eric.dodds@unl.edu.ORCID http://orcid.org/0000-0002-7721-394X

Funding

Targeted mass spectrometry approaches to understand CART processing and recepter interactionsP20GM113126 · NIGMS · UNIVERSITY OF NEBRASKA LINCOLN · PI GUO, JIANTAO · 2016 to 2025
$20.8M
Molecular Mechanisms of DiseaseT32GM107001 · NIGMS · UNIVERSITY OF NEBRASKA LINCOLN · PI BECKER, DONALD F, BLACK, PAUL N. · 2015 to 2019
$1.0M
National Science Foundation 1460829National Science Foundation 1507989NIGMS NIH HHS P20 GM113126NIGMS NIH HHS T32 GM107001NIH HHS T32GM107001
6 · The paper itself

Abstract

Steroids represent an interesting class of small biomolecules due to their use as biomarkers and their status as scheduled drugs. Although the analysis of steroids is complicated by the potential for many isomers, ion mobility spectrometry (IMS) has previously shown promise for the rapid separation of steroid isomers. This work is aimed at the further development of IMS separation for the analysis of steroids. Here, traveling wave ion mobility spectrometry (TWIMS) was applied to the study of group I metal adducted steroids and their corresponding multimers for five sets of isomers. Each set of isomers had a minimum of one dimeric metal ion adduct that exhibited a resolution greater than one (i.e., approaching baseline resolution). Additionally, ion-neutral collision cross sections (CCSs) were measured using polyalanine as a calibrant, which may provide an additional metric contributing to analyte identification. Where possible, measured CCSs were compared to previously reported values. When measuring CCSs of steroid isomers using polyalanine as the calibrant, nitrogen CCS values were within 1.0% error for monomeric sodiated adducts and slightly higher for the dimeric sodiated adducts. Overall, TWIMS was found to successfully separate steroids as dimeric adducts of group I metals. Graphical Abstract ᅟ.

Indexed as

CalibrationIon Mobility SpectrometryIsomerismMetalsMetals, LightNitrogenPeptidesSteroidsMetalsMetals, LightNitrogenPeptidespolyalanineSteroidsCollision cross sectionIon mobility spectrometryIsomer discriminationMetal ion adductionSteroids

Identifiers

PMID30414066
PMCPMC6551524

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.