ArticleJournal of applied clinical medical physics2019
Monte Carlo and analytic modeling of an Elekta Infinity linac with Agility MLC: Investigating the significance of accurate model parameters for small radiation fields.
Article in Journal of applied clinical medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed.
- Evaluating Monaco 6.2.2 in complex radiotherapy across matched LINACs: improved MLC modelling and dose accuracy with virtual source model 2.0.Physical and engineering sciences in medicine · 2025Article
- Evaluation of the accuracy of an enhanced MLC leaf model for Linac-based stereotactic radiosurgery.Journal of applied clinical medical physics · 2025Article
- Dosimetric investigation of small fields in radiotherapy measurements using Monte Carlo simulations, CC04 ionization chamber, and razor diode.Physical and engineering sciences in medicine · 2025Article
- Comparative analysis of VMAT plans on Halcyon and infinity for lung cancer radiotherapy.PloS one · 2025Article
- Article
- Effect of simultaneous integrated boost concepts on photoneutron and distant out-of-field doses in VMAT for prostate cancer.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2024Article
- Improving the modelling of a multi-leaf collimator with tilted leaf sides used in radiotherapy.Physics and imaging in radiation oncology · 2024Article
- Transmission probability filter optimization for Agility MLC in Monaco treatment planning system.Journal of applied clinical medical physics · 2023Article
- Challenges in modeling the Agility multileaf collimator in treatment planning systems and current needs for improvement.Medical physics · 2022Article
- Determination and validation of the initial beam parameters of Elekta Agility collimator head by Monte Carlo simulations.Physical and engineering sciences in medicine · 2022Article
- Monte Carlo modeling of the Elekta Versa HD and patient dose calculation with EGSnrc/BEAMnrc.Journal of applied clinical medical physics · 2022Article
- Development of a virtual source model for Monte Carlo-based independent dose calculation for varian linac.Journal of applied clinical medical physics · 2022Article
- Investigation of pixel scale calibration on the Elekta iView electronic portal imager.Journal of applied clinical medical physics · 2021Article
- Determination of the Small-Field Output Factor for 6 MV Photon Beam Using EGSnrc Monte Carlo.Journal of medical physicsArticle
- A Comprehensive Dosimetric and Plan Quality Evaluation of Non-coplanar VMAT With Flattening Filter-free Versus Flattened Beams for Hippocampal-Avoidance Whole-Brain Radiotherapy: A Multi-Platform Study on Elekta Infinity and UIH uRT-Linac Systems.Technology in cancer research & treatmentArticle
- Design and Evaluation of Structural Shielding of a Typical Radiotherapy Facility Using EGSnrc Monte Carlo Code.Journal of medical physicsArticle
- Monte carlo model and output factors of elekta infinity™ 6 and 10 MV photon beam.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation OncologyArticle
- Sensitivity Analysis of a 6 MeV Photon Beam Monte Carlo Model.Journal of medical signals and sensorsArticle
- Multileaf Collimator Modeling and Commissioning for Complex Radiation Treatment Plans Using 2-Dimensional (2D) Diode Array MapCHECK2.Technology in cancer research & treatmentArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
purposeTo explain the deviation observed between measured and Monaco calculated dose profiles for a small field (i.e., alternating open-closed MLC pattern). A Monte Carlo (MC) model of an Elekta Infinity linac with Agility MLC was created and validated against measurements. In addition, an analytic model which predicts the fluence at the isocenter plane was used to study the impact of multiple beam parameters on the accuracy of dose calculations for small fields.
methodsA detailed MC model of a 6 MV Elekta Infinity linac with Agility MLC was created in EGSnrc/BEAMnrc and validated against measurements. An analytic model using primary and secondary virtual photon sources was created and benchmarked against the MC simulations and the impact of multiple beam parameters on the accuracy of the model for a small field was investigated. Both models were used to explain discrepancies observed between measured/EGSnrc simulated and Monaco calculated dose profiles for alternating open-closed MLC leaves.
resultsMC-simulated dose profiles (PDDs, cross- and in-line profiles, etc.) were found to be in very good agreements with measurements. The best fit for the leaf bank rotation was found to be 9 mrad to model the defocusing of Agility MLC. Moreover, a very good agreement was observed between results from the analytic model and MC simulations for a small field. Modifying the radial size of the incident electron beam in the BEAMnrc model improved the agreement between Monaco and EGSnrc calculated dose profiles by approximately 16% and 30% in the position of maxima and minima, respectively.
conclusionAccurate modeling of the full-width-half-maximum (FWHM) of the primary photon source as well as the MLC leaf design (leaf bank rotation, etc.) is essential for accurate calculations of dose delivered by small radiation fields when using virtual source or MC models of the beam.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.