Evidence map›Paper›PMID 30407401›Full record

ArticleMicromachines2016

Development of a Whole Blood Paper-Based Device for Phenylalanine Detection in the Context of PKU Therapy Monitoring.

Robert Robinson, Liam Wong, Raymond J Monnat, Elain Fu

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
3.0field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 50 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Robert RobinsonSchool of Chemical, Biological, and Environmental Engineering, Oregon State University, Corvallis, OR 97331, USA. robinrob@oregonstate.edu.
Liam WongSchool of Chemical, Biological, and Environmental Engineering, Oregon State University, Corvallis, OR 97331, USA. wonglia@oregonstate.edu.ORCID 0000-0002-1588-2806
Raymond J MonnatDepartments of Pathology and Genome Sciences, University of Washington, Seattle, WA 98195, USA. monnat@u.washington.edu.
Elain FuSchool of Chemical, Biological, and Environmental Engineering, Oregon State University, Corvallis, OR 97331, USA. elain.fu@oregonstate.edu.
Oregon State University · USUniversity of Washington · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Laboratory-based testing does not allow for the sufficiently rapid return of data to enable optimal therapeutic monitoring of patients with metabolic diseases such as phenylketonuria (PKU). The typical turn-around time of several days for current laboratory-based testing is too slow to be practically useful for effective monitoring or optimizing therapy. This report describes the development of a rapid, paper-based, point-of-care device for phenylalanine detection using a small volume (40 μL) of whole blood. The quantitative resolution and reproducibility of this device with instrumented readout are described, together with the potential use of this device for point-of-care monitoring by PKU patients.

Indexed as

colorimetric readoutpaper-based devicephenylalanine detectionphenylketonuriawhole-blood assay

Identifiers

PMID30407401
PMCPMC6190008
OpenAlexW2277834442

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.