ReviewMicromachines2016
A Review of Biomedical Centrifugal Microfluidic Platforms.
Review in Micromachines, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 35 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
35 citing papers in PubMed.
- Microfluidic Electrochemical Biosensor for the Detection of Platelet Factor 4 Antibody-Mediated Thrombotic Disorders.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Article
- Enhanced One-Pot Dual-CRISPR-Based Assay Lyophilized on a 3D-Printed Disc for Field-Deployable Multiplex Bacteria Detection.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Article
- PDMS SlipChip: Optimizing Sealing, Slipping, and Biocompatibility Using Low-Viscosity Silicone Oils.Micromachines · 2025Article
- A passive flow microreactor for urine creatinine test.Microsystems & nanoengineering · 2025Article
- Novel thermoplastic microvalves based on an elastomeric cyclic olefin copolymer.Lab on a chip · 2024Article
- Article
- Article
- An Automated Centrifugal Microfluidic Platform for Efficient Multistep Blood Sample Preparation and Clean-Up towards Small Ion-Molecule Analysis.Micromachines · 2023Article
- Recent Developments in Inertial and Centrifugal Microfluidic Systems along with the Involved Forces for Cancer Cell Separation: A Review.Sensors (Basel, Switzerland) · 2023Review
- Lab-on-a-Chip Electrochemical Biosensors for Foodborne Pathogen Detection: A Review of Common Standards and Recent Progress.Biosensors · 2023Review
- Digital process control of multi-step assays on centrifugal platforms using high-low-high rotational-pulse triggered valving.PloS one · 2023Article
- Detection of Tomato Ringspot Virus Based on Microfluidic Impedance Sensor.Micromachines · 2022Article
- Elastic membrane enabled inward pumping for liquid manipulation on a centrifugal microfluidic platform.Biomicrofluidics · 2022Article
- Design and fabrication of a low-cost wireless camera imaging system for centrifugal microfluidics.HardwareX · 2022Article
- Development of a proof-of-concept microfluidic portable pathogen analysis system for water quality monitoring.The Science of the total environment · 2022Article
- Monolithic, 3D-printed lab-on-disc platform for multiplexed molecular detection of SARS-CoV-2.Sensors and actuators. B, Chemical · 2022Article
- How to Control the Microfluidic Flow and Separate the Magnetic and Non-Magnetic Particles in the Runner of a Disc.Micromachines · 2021Article
- Faster, better, and cheaper: harnessing microfluidics and mass spectrometry for biotechnology.RSC chemical biology · 2021Review
- Secure Air Traffic Control at the Hub of Multiplexing on the Centrifugo-Pneumatic Lab-on-a-Disc Platform.Micromachines · 2021Article
- Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Centrifugal microfluidic or lab-on-a-disc platforms have many advantages over other microfluidic systems. These advantages include a minimal amount of instrumentation, the efficient removal of any disturbing bubbles or residual volumes, and inherently available density-based sample transportation and separation. Centrifugal microfluidic devices applied to biomedical analysis and point-of-care diagnostics have been extensively promoted recently. This paper presents an up-to-date overview of these devices. The development of biomedical centrifugal microfluidic platforms essentially covers two categories: (i) unit operations that perform specific functionalities, and (ii) systems that aim to address certain biomedical applications. With the aim to provide a comprehensive representation of current development in this field, this review summarizes progress in both categories. The advanced unit operations implemented for biological processing include mixing, valving, switching, metering and sequential loading. Depending on the type of sample to be used in the system, biomedical applications are classified into four groups: nucleic acid analysis, blood analysis, immunoassays, and other biomedical applications. Our overview of advanced unit operations also includes the basic concepts and mechanisms involved in centrifugal microfluidics, while on the other hand an outline on reported applications clarifies how an assembly of unit operations enables efficient implementation of various types of complex assays. Lastly, challenges and potential for future development of biomedical centrifugal microfluidic devices are discussed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.