Evidence map›Paper›PMID 30400469›Full record

ArticleMicromachines2017

Simulation, Fabrication and Analysis of Silver Based Ascending Sinusoidal Microchannel (ASMC) for Implant of Varicose Veins.

Muhammad Javaid Afzal, Shahzadi Tayyaba, Muhammad Waseem Ashraf, M Khalid Hossain, M Jalal Uddin, Nitin Afzulpurkar

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 19 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 3 countries.

Muhammad Javaid AfzalDepartment of Physics, The University of Lahore, Lahore 54000, Pakistan. javaidphy@gmail.com.ORCID 0000-0003-2786-3765
Shahzadi TayyabaDepartment of Computer Engineering, The University of Lahore, Lahore 54000, Pakistan. shahzadi.tayyaba@hotmail.com.
Muhammad Waseem AshrafDepartment of Physics (Electronics), GC University, Lahore 54000, Pakistan. muhammad.waseem.ashraf@gmail.com.
M Khalid HossainInstitute of Electronics, Atomic Energy Research Establishment, Bangladesh Atomic Energy Commission, Dhaka 1349, Bangladesh. khalid.baec@baec.gov.bd.ORCID 0000-0003-4595-6367
M Jalal UddinDepartment of Applied Physics, Electronics and Communication Engineering; Islamic University, Khustia 7003, Bangladesh. mju.aece@gmail.com.
Nitin AfzulpurkarDepartment of Mechanical Engineering Technology (MCET), Higher Colleges of Technology (HCT), Ras al-Khaimah POBox 4793, UAE. afzulpurkar.n@gmail.com.
University of Lahore · PKBangladesh Atomic Energy Commission · BDGovernment College University, Lahore · PKHigher Colleges of Technology · AEIslamic University · BD

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Bioengineered veins can benefit humans needing bypass surgery, dialysis, and now, in the treatment of varicose veins. The implant of this vein in varicose veins has significant advantages over the conventional treatment methods. Deep vein thrombosis (DVT), vein patch repair, pulmonary embolus, and tissue-damaging problems can be solved with this implant. Here, the authors have proposed biomedical microdevices as an alternative for varicose veins. MATLAB and ANSYS Fluent have been used for simulations of blood flow for bioengineered veins. The silver based microchannel has been fabricated by using a micromachining process. The dimensions of the silver substrates are 51 mm, 25 mm, and 1.1 mm, in length, width, and depth respectively. The dimensions of microchannels grooved in the substrates are 0.9 mm in width and depth. The boundary conditions for pressure and velocity were considered, from 1.0 kPa to 1.50 kPa, and 0.02 m/s to 0.07 m/s, respectively. These are the actual values of pressure and velocity in varicose veins. The flow rate of 5.843 (0.1 nL/s) and velocity of 5.843 cm/s were determined at Reynolds number 164.88 in experimental testing. The graphs and results from simulations and experiments are in close agreement. These microchannels can be inserted into varicose veins as a replacement to maintain the excellent blood flow in human legs.

Indexed as

ANSYSbioengineered veinbioMEMSfuzzy logicmicrochannelsmicrofluidicsvaricose vein

Identifiers

PMID30400469
PMCPMC6189736
OpenAlexW2754613855

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.