Evidence map›Paper›PMID 30400265›Full record

ArticleBiosensors2018

PEDOT Coated Thick Film Electrodes for In Situ Detection of Cell Adhesion in Cell Cultures.

Heike Bartsch, Ralf Peipmann, Maren Klett, Dana Brauer, Andreas Schober, Jens Müller

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 5 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Heike BartschTechnische Universität Ilmenau, Institute of Micro- and Nanotechnologies, Gustav-Kirchhoff-Straße 7, 98693 Ilmenau, Germany. heike.bartsch@tu-ilmenau.de.ORCID 0000-0001-7199-7600
Ralf PeipmannTechnische Universität Ilmenau, Institute of Micro- and Nanotechnologies, Gustav-Kirchhoff-Straße 7, 98693 Ilmenau, Germany. ralf.peipmann@tu-ilmenau.de.ORCID 0000-0001-8719-4925
Maren KlettTechnische Universität Ilmenau, Institute of Micro- and Nanotechnologies, Gustav-Kirchhoff-Straße 7, 98693 Ilmenau, Germany. maren.klett@tu-ilmenau.de.
Dana BrauerTechnische Universität Ilmenau, Institute of Micro- and Nanotechnologies, Gustav-Kirchhoff-Straße 7, 98693 Ilmenau, Germany. dana.brauer@tu-ilmenau.de.
Andreas SchoberTechnische Universität Ilmenau, Institute of Micro- and Nanotechnologies, Gustav-Kirchhoff-Straße 7, 98693 Ilmenau, Germany. andreas.schober@tu-ilmenau.de.
Jens MüllerTechnische Universität Ilmenau, Institute of Micro- and Nanotechnologies, Gustav-Kirchhoff-Straße 7, 98693 Ilmenau, Germany. jens.mueller@tu-ilmenau.de.
Technische Universität Ilmenau · DE

Funding

Bundesministerium für Wissenschaft und Forschung 03WKCB010Carl-Zeiss-Stiftung 0563-2.8/399/1Deutsche Forschungsgemeinschaft Open Access Publication Fund of the Technische Universität Ilmenau
6 · The paper itself

Abstract

Low temperature cofired ceramics (LTCC) provide a technology for the 3-dimensional integration of sensor arrays into bioreactors covering dimensions of several hundred micrometers. Since optical control in such assemblies is not possible, the in situ detection of cell adhesion on impedance electrodes with high spatial resolution would deliver crucial information. A current limitation is the increasing impedance of microelectrodes with decreasing diameter. This study evaluates the suitability of thick film gold electrodes, pristine and coated with electropolymerized poly(3,4-ethylenedioxythiophene) (PEDOT), for the detection of cell adhesion on the electrode surface. The impedance as criterion for cell attachment is measured with a recording system for electroactive cells with the aim of improving usability. Two cell cultures with different adhesion characteristic are used for adhesion assessment on planar test chips. The impedance increase measured on individual PEDOT coated electrodes due to tight contact of cells reaches a factor of 6.8 in cultures of well-adherent HepG2 cells. Less adhered NG108-15 cells produce a maximum impedance increase by a factor of 2.6. Since the electrode impedance is significantly reduced by PEDOT coating, a reduction of the electrode diameter to values below 100 µm and spatially resolved detection is possible. The results encourage further studies using PEDOT coated thick film electrodes as bio-electronic-interfaces. We presume that such miniaturized electrodes are suitable for 3-dimensional recordings in electroactive cell cultures, providing information of local cell adhesion at the same time.

Indexed as

ElectrodesBridged Bicyclo Compounds, HeterocyclicCell AdhesionHep G2 CellsHumansPolymersBridged Bicyclo Compounds, Heterocyclicpoly(3,4-ethylene dioxythiophene)Polymerscell adhesionelectroactive cellsimpedancein situ monitoringin vitro cell cultureLTCCneuronal cellsPEDOTspatial resolutionthick film electrodes

Identifiers

PMID30400265
PMCPMC6315667
OpenAlexW2899335196

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.