Evidence map›Paper›PMID 30396022›Full record

ArticleBiosensors & bioelectronics2019

Label free thrombin detection in presence of high concentration of albumin using an aptamer-functionalized nanoporous membrane.

Agnivo Gosai, Brendan Shin Hau Yeah, Marit Nilsen-Hamilton, Pranav Shrotriya

Open access · greenAbstract readEvaluation Study
In one paragraph

Article in Biosensors & bioelectronics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.9field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 43 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Agnivo GosaiDepartment of Mechanical Engineering,Iowa State University, 2019 Black Engineering Building, Ames, IA 50011, United States.
Brendan Shin Hau YeahDepartment of Mechanical Engineering,Iowa State University, 2019 Black Engineering Building, Ames, IA 50011, United States.
Marit Nilsen-HamiltonDepartment of Biochemistry, Biophysics and Molecular Biology, Iowa State University, Ames, IA 50011, United States; Aptalogic Inc, United States.
Pranav ShrotriyaDepartment of Mechanical Engineering,Iowa State University, 2019 Black Engineering Building, Ames, IA 50011, United States. Electronic address: shrotriy@iastate.edu.
Iowa State University · US

Funding

Early diagnosis of acute kidney injury by aptasensorsR44DK098031 · NIDDK · APTALOGIC, INC · PI ILGU, MUSLUM · 2015 to 2017
$990k
Detecting Ebola Virus InfectionsR43AI118139 · NIAID · APTALOGIC, INC · PI HAMILTON, RICHARD T · 2015 to 2016
$683k
Early diagnosis of acute kidney injury by aptasensorsR43DK098031 · NIDDK · APTALOGIC, INC · PI ILGU, MUSLUM · 2013 to 2013
$151k
NIAID NIH HHS R43 AI118139NIDDK NIH HHS R43 DK098031NIDDK NIH HHS R44 DK098031
6 · The paper itself

Abstract

Nanoporous alumina membranes have become a ubiquitous biosensing platform for a variety of applications and aptamers are being increasingly utilized as recognition elements in protein sensing devices. Combining the advantages of the two, we report label-free sensitive detection of human α-thrombin by an aptamer-functionalized nanoporous alumina membrane using a four-electrode electrochemical cell. The sensor response to α-thrombin was determined in the presence of a high concentration (500 μM) of human serum albumin (HSA) as an interfering protein in the background. The sensor sensitivity was also characterized against γ-thrombin, which is a modified α-thrombin lacking the aptamer binding epitope. The detection limit, within an appreciable signal/noise ratio, was 10 pM of α-thrombin in presence of 500 μM HSA. The proposed scheme involves the use of minimum reagents/sample preparation steps, has appreciable response in presence of high concentrations of interfering molecules and is readily amenable to miniaturization by association with existing-chip based electrical systems for application in point-of-care diagnostic devices.

Indexed as

NanoporesAptamers, NucleotideBiosensing TechniquesElectrodesEquipment DesignHumansLimit of DetectionMembranes, ArtificialSerum AlbuminThrombinAptamers, NucleotideMembranes, ArtificialSerum AlbuminThrombinthrombin aptamerAptamerEISNanoporous alumina membraneSerum albuminThrombin

Identifiers

PMID30396022
PMCPMC6383723
OpenAlexW2896245579

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.