ArticleMagnetic resonance in medicine2019
3D dynamic MRI of the vocal tract during natural speech.
Article in Magnetic resonance in medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed, 39 citations in OpenAlex.
- Online Spatiotemporally Constrained Reconstruction for Real-Time Interactive MRI.Magnetic resonance in medicine · 2026Article
- Clean Self-Supervised MRI Reconstruction from Noisy, Sub-Sampled Training Data with Robust SSDU.Bioengineering (Basel, Switzerland) · 2024Article
- Estimating Palatal and Pharyngeal Muscle Contraction in Hindi Syllable Pronunciation using Computational Modeling.Indian journal of plastic surgery : official publication of the Association of Plastic Surgeons of India · 2024Article
- Quantifying articulatory variations across phonological environments: An atlas-based approach using dynamic magnetic resonance imaging.The Journal of the Acoustical Society of America · 2024Article
- Real-time water/fat imaging at 0.55T with spiral out-in-out-in sampling.Magnetic resonance in medicine · 2024Article
- Optimization of 3D dynamic speech MRI: Poisson-disc undersampling and locally higher-rank reconstruction through partial separability model with regional optimized temporal basis.Magnetic resonance in medicine · 2024Article
- A Theoretical Framework for Self-Supervised MR Image Reconstruction Using Sub-Sampling via Variable Density Noisier2Noise.IEEE transactions on computational imaging · 2023Article
- Enhancing linguistic research through 2-mm isotropic 3D dynamic speech MRI optimized by sparse temporal sampling and low-rank reconstruction.Magnetic resonance in medicine · 2023Article
- 3D Dynamic Spatiotemporal Atlas of the Vocal Tract during Consonant-Vowel Production from 2D Real Time MRI.Journal of imaging · 2022Article
- Dynamic MRI of swallowing: real-time volumetric imaging at 12 frames per second at 3 T.Magma (New York, N.Y.) · 2022Article
- Real-Time Magnetic Resonance Imaging.Journal of magnetic resonance imaging : JMRI · 2022Review
- 4D magnetic resonance imaging atlas construction using temporally aligned audio waveforms in speech.The Journal of the Acoustical Society of America · 2021Article
- Aliasing artifact reduction in spiral real-time MRI.Magnetic resonance in medicine · 2021Article
- A multispeaker dataset of raw and reconstructed speech production real-time MRI video and 3D volumetric images.Scientific data · 2021Article
- Rotated spiral RARE for high spatial and temporal resolution volumetric arterial spin labeling acquisition.NeuroImage · 2020Article
- Realistic Dynamic Numerical Phantom for MRI of the Upper Vocal Tract.Journal of imaging · 2020Article
- Intermittently tagged real-time MRI reveals internal tongue motion during speech production.Magnetic resonance in medicine · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
Abstract
purposeTo develop and evaluate a technique for 3D dynamic MRI of the full vocal tract at high temporal resolution during natural speech.
methodsWe demonstrate 2.4 × 2.4 × 5.8 mm
resultsThis technique captured known dynamics of vocal tract articulators during natural speech tasks including tongue gestures during the production of consonants "s" and "l" and of consonant-vowel syllables, and was additionally consistent with 2D dynamic MRI. Coordination of lingual (tongue) movements for consonants is demonstrated via volume-of-interest analysis. Vocal tract area function dynamics revealed critical lingual constriction events along the length of the vocal tract for consonants and vowels.
conclusionWe demonstrate feasibility of 3D dynamic MRI of the full vocal tract, with spatiotemporal resolution adequate to visualize lingual movements for consonants and vocal tact shaping during natural productions of consonant-vowel syllables, without requiring multiple repetitions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.