Evidence map›Paper›PMID 30388141›Full record

ArticlePloS one2018

Impact of hemodialysis on cardiovascular system assessed by pulse wave analysis.

Malgorzata Debowska, Jan Poleszczuk, Wojciech Dabrowski, Alicja Wojcik-Zaluska, Wojciech Zaluska, Jacek Waniewski

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.7field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Designing an Implementable Clinical Prediction Model for Near-Term Mortality and Long-Term Survival in Patients on Maintenance Hemodialysis.American journal of kidney diseases : the official journal of the National Kidney Foundation · 2024
    Article
  3. Research Progress and Clinical Value of Subendocardial Viability Ratio.Journal of the American Heart Association · 2024
    Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Malgorzata DebowskaDepartment for Mathematical Modeling of Physiological Processes, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland.ORCID 0000-0001-8741-7930
Jan PoleszczukDepartment for Mathematical Modeling of Physiological Processes, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland.
Wojciech DabrowskiDepartment of Anesthesiology and Intensive Therapy, Medical University of Lublin, Lublin, Poland.
Alicja Wojcik-ZaluskaDepartment of Physical Therapy and Rehabilitation, Medical University of Lublin, Lublin, Poland.
Wojciech ZaluskaDepartment of Nephrology, Medical University of Lublin, Lublin, Poland.
Jacek WaniewskiDepartment for Mathematical Modeling of Physiological Processes, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland.
Institute of Biocybernetics and Biomedical Engineering · PLMedical University of Lublin · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Valuable information about cardiovascular system can be derived from the shape of aortic pulse wave being the result of reciprocal interaction between heart and vasculature. Pressure profiles in ascending aorta were obtained from peripheral waveforms recorded non-invasively (SphygmoCor, AtCor Medical, Australia) before, during and after hemodialysis sessions performed after 3-day and 2-day interdialytic intervals in 35 anuric, prevalent hemodialysis patients. Fluid status was assessed by Body Composition Monitor (Fresenius Medical Care, Bad Homburg, Germany) and online hematocrit monitoring device (CritLine, HemaMetrics, Utah). Systolic pressure and ejection duration decreased during dialysis. Augmentation index remained stable at 30 ± 13% throughout hemodialysis session despite the decrease of augmented pressure and pulse height. Subendocardial viability ratio (SEVR) determined after 3-day and 2-day interdialytic intervals increased during the sessions by 43.8 ± 26.6% and 26.1 ± 25.4%, respectively. Hemodialysis performed after 3-day and 2-day interdialytic periods reduced significantly overhydration by 2.4 ± 1.0 L and 1.8 ± 1.2 L and blood volume by 16.3 ± 9.7% and 13.7 ± 8.9%, respectively. Intradialytic increase of SEVR correlated with ultrafiltration rate (R = 0.39, p-value < 0.01), reduction in overhydration (R = -0.57, p-value < 0.001) and blood volume drop (R = -0.38, p-value < 0.01). The strong correlation between the decrease of overhydration during hemodialysis and increase in SEVR confirmed that careful fluid management is crucial for proper cardiac function. Hemodialysis affected cardiovascular system with the parameters derived from pulse-wave-analysis (systolic and augmented pressures, pulse height, ejection duration, SEVR) being significantly different at the end of dialysis from those before the session. Combination of pulse-wave-analysis with the monitoring of overhydration provides a new insight into the impact of hemodialysis on cardiovascular system.

Indexed as

Cardiovascular Physiological PhenomenaPulse Wave AnalysisRenal DialysisAdultAgedAged, 80 and overAortaBiomarkersBlood VolumeBody CompositionCardiovascular SystemFemaleHumansMaleMiddle AgedTime FactorsBiomarkers

Identifiers

PMID30388141
PMCPMC6279117
OpenAlexW2899200404

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.