Evidence map›Paper›PMID 30386133›Full record

ArticleKorean journal of radiology

Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease.

Jee Young Min, Sung Min Ko, In Young Song, Jung Geun Yi, Hweung Kon Hwang, Je Kyoun Shin

Abstract read
In one paragraph

Article in Korean journal of radiology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 3 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 3 syntheses or guidelines pooled it.

  1. Pooled it
  2. Guideline
  3. Guideline
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jee Young MinDepartment of Radiology, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul 05030, Korea.
Sung Min KoDepartment of Radiology, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul 05030, Korea.
In Young SongDepartment of Radiology, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul 05030, Korea.
Jung Geun YiDepartment of Radiology, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul 05030, Korea.
Hweung Kon HwangDepartment of Cardiology, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul 05030, Korea.
Je Kyoun ShinDepartment of Thoracic Surgery, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul 05030, Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To compare the diagnostic performance of cardiovascular magnetic resonance (CMR) myocardial perfusion at 1.5- and 3-tesla (T) for detecting significant coronary artery disease (CAD), with invasive coronary angiography (ICA) as the reference method. Materials and Methods: We prospectively enrolled 281 patients (age 62.4 ± 8.3 years, 193 men) with suspected or known CAD who had undergone 1.5T or 3T CMR and ICA. Two independent radiologists interpreted perfusion defects. With ICA as the reference standard, the diagnostic performance of 1.5T and 3T CMR for identifying significant CAD (≥ 50% diameter reduction of the left main and ≥ 70% diameter reduction of other epicardial arteries) was determined. Results: No differences were observed in baseline characteristics or prevalence of CAD and old myocardial infarction (MI) using 1.5T (n = 135) or 3T (n = 146) systems. Sensitivity, specificity, positive and negative predictive values, and area under the receiver operating characteristic curve (AUC) for detecting significant CAD were similar between the 1.5T (84%, 64%, 74%, 76%, and 0.75 per patient and 68%, 83%, 66%, 84%, and 0.76 per vessel) and 3T (80%, 71%, 71%, 80%, and 0.76 per patient and 75%, 86%, 64%, 91%, and 0.81 per vessel) systems. In patients with multi-vessel CAD without old MI, the sensitivity, specificity, and AUC with 3T were greater than those with 1.5T on a per-vessel basis (71% vs. 36%, 92% vs. 69%, and 0.82 vs. 0.53, respectively). Conclusion: 3T CMR has similar diagnostic performance to 1.5T CMR in detecting significant CAD, except for higher diagnostic performance in patients with multi-vessel CAD without old MI.

Indexed as

AdultAgedArea Under CurveCoronary Artery DiseaseCoronary VesselsFemaleHumansMagnetic Resonance Imaging, CineMaleMiddle AgedMyocardial InfarctionProspective StudiesROC CurveSensitivity and SpecificitySeverity of Illness IndexAtherosclerosisCoronary artery diseaseInvasive coronary angiography, 3 teslaMagnetic resonance imagingMyocardial perfusion

Identifiers

PMID30386133
PMCPMC6201977

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.