ArticleSensors (Basel, Switzerland)2018
Validation of Instantaneous Respiratory Rate Using Reflectance PPG from Different Body Positions.
Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed.
- Mental Stress Detection Using Physiological Sensors and Artificial Intelligence: A Review.Sensors (Basel, Switzerland) · 2026Review
- A late fusion multi-task learning for respiratory waveform and rate estimation from photoplethysmography.PloS one · 2026Article
- Elucidating the Reactivity of Reflectance-Based Core-Body Photoplethysmogram to Posture and Respiratory Changes.IEEE sensors journal · 2025Article
- Quality-Aware Signal Processing Mechanism of PPG Signal for Long-Term Heart Rate Monitoring.Sensors (Basel, Switzerland) · 2024Article
- Cuff-Less Blood Pressure Prediction Based on Photoplethysmography and Modified ResNet.Bioengineering (Basel, Switzerland) · 2023Article
- PPG2EMG: Estimating Upper-Arm Muscle Activities and EMG from Wrist PPG Values.Sensors (Basel, Switzerland) · 2023Article
- Feasibility of Electrodermal Activity and Photoplethysmography Data Acquisition at the Foot Using a Sock Form Factor.Sensors (Basel, Switzerland) · 2023Article
- Comparison of Three Prototypes of PPG Sensors for Continual Real-Time Measurement in Weak Magnetic Field.Sensors (Basel, Switzerland) · 2022Article
- Breathing Rate Estimation from Head-Worn Photoplethysmography Sensor Data Using Machine Learning.Sensors (Basel, Switzerland) · 2022Article
- Clinical evaluation of stretchable and wearable inkjet-printed strain gauge sensor for respiratory rate monitoring at different measurements locations.Journal of clinical monitoring and computing · 2021Article
- Wearable technology to inform the prediction and diagnosis of cardiorespiratory events: a scoping review.PeerJ · 2021Article
- Derivation of Respiratory Metrics in Health and Asthma.Sensors (Basel, Switzerland) · 2020Article
- First-Step PPG Signal Analysis for Evaluation of Stress Induced during Scanning in the Open-Air MRI Device.Sensors (Basel, Switzerland) · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Respiratory rate (RR) is a key parameter used in healthcare for monitoring and predicting patient deterioration. However, continuous and automatic estimation of this parameter from wearable sensors is still a challenging task. Various methods have been proposed to estimate RR from wearable sensors using windowed segments of the data; e.g., often using a minimum of 32 s. Little research has been reported in the literature concerning the instantaneous detection of respiratory rate from such sources. In this paper, we develop and evaluate a method to estimate instantaneous respiratory rate (IRR) from body-worn reflectance photoplethysmography (PPG) sensors. The proposed method relies on a nonlinear time-frequency representation, termed the wavelet synchrosqueezed transform (WSST). We apply the latter to derived modulations of the PPG that arise from the act of breathing.We validate the proposed algorithm using (i) a custom device with a PPG probe placed on various body positions and (ii) a commercial wrist-worn device (WaveletHealth Inc., Mountain View, CA, USA). Comparator reference data were obtained via a thermocouple placed under the nostrils, providing ground-truth information concerning respiration cycles. Tracking instantaneous frequencies was performed in the joint time-frequency spectrum of the (4 Hz re-sampled) respiratory-induced modulation using the WSST, from data obtained from 10 healthy subjects. The estimated instantaneous respiratory rates have shown to be highly correlated with breath-by-breath variations derived from the reference signals. The proposed method produced more accurate results compared to averaged RR obtained using 32 s windows investigated with overlap between successive windows of (i) zero and (ii) 28 s. For a set of five healthy subjects, the averaged similarity between reference RR and instantaneous RR, given by the longest common subsequence (LCSS) algorithm, was calculated as 0.69; this compares with averaged similarity of 0.49 using 32 s windows with 28 s overlap between successive windows. The results provide insight into estimation of IRR and show that upper body positions produced PPG signals from which a better respiration signal was extracted than for other body locations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.