Evidence map›Paper›PMID 30383805›Full record

ArticlePloS one2018

Biomimetic extracellular matrix coatings improve the chronic biocompatibility of microfabricated subdural microelectrode arrays.

Flavia Vitale, Wendy Shen, Nicolette Driscoll, Justin C Burrell, Andrew G Richardson, Oladayo Adewole, Brendan Murphy, Akshay Ananthakrishnan, Hanju Oh, Theodore Wang and 4 more

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
1.2field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 29 citations in OpenAlex.

  1. Review
  2. Review
  3. Full-Stack Architectures for Intelligent Brain-Computer Interfaces.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  4. Review
  5. Review
  6. Review
  7. Article
  8. Review
  9. β-Estradiol 17-acetate enhances theNeural regeneration research · 2023
    Article
  10. Review
  11. Review
  12. Review
  13. Review
  14. Article
  15. Article
  16. Bioactive Neuroelectronic Interfaces.Frontiers in neuroscience · 2019
    Review
  17. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors at 2 institutions in 1 country.

Flavia VitaleCenter for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia PA, United States of America.ORCID 0000-0001-8644-550X
Wendy ShenDepartment of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia PA, United States of America.
Nicolette DriscollCenter for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia PA, United States of America.
Justin C BurrellCenter for Neurotrauma, Neurodegeneration & Restoration, Corporal Michael J. Crescenz VA Medical Center, Philadelphia PA, United States of America.
Andrew G RichardsonDepartment of Neurosurgery, University of Pennsylvania, Philadelphia PA, United States of America.
Oladayo AdewoleCenter for Neurotrauma, Neurodegeneration & Restoration, Corporal Michael J. Crescenz VA Medical Center, Philadelphia PA, United States of America.
Brendan MurphyCenter for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia PA, United States of America.ORCID 0000-0003-3021-6286
Akshay AnanthakrishnanDepartment of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia PA, United States of America.ORCID 0000-0002-2791-9514
Hanju OhDepartment of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia PA, United States of America.
Theodore WangDepartment of Bioengineering, University of Pennsylvania, Philadelphia PA, United States of America.
Timothy H LucasCenter for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia PA, United States of America.
D Kacy CullenCenter for Neurotrauma, Neurodegeneration & Restoration, Corporal Michael J. Crescenz VA Medical Center, Philadelphia PA, United States of America.
Mark G AllenDepartment of Electrical and Systems Engineering, University of Pennsylvania, Philadelphia PA, United States of America.
Brian LittCenter for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia PA, United States of America.
University of Pennsylvania · USPhiladelphia VA Medical Center · US

Funding

Virtual Resection to Treat EpilepsyR01NS099348 · NINDS · UNIVERSITY OF PENNSYLVANIA · PI BASSETT, DANIELLE SMITH, LITT, BRIAN · 2016 to 2019
$2.3M
Biological 'Living Electrodes' Using Tissue Engineered Axonal Tracts to Probe and Modulate the Nervous SystemU01NS094340 · NINDS · UNIVERSITY OF PENNSYLVANIA · PI CULLEN, DANIEL KACY · 2015 to 2017
$2.0M
Transplantable Micro-Tissue Engineered Neural Networks to Restore the Nigrostriatal Pathway in Parkinson's DiseaseI01BX003748 · VA · PHILADELPHIA VA MEDICAL CENTER · PI CULLEN, DANIEL KACY · 2017 to 2022
–
BLRD VA I01 BX003748NINDS NIH HHS R01 NS099348NINDS NIH HHS U01 NS094340
6 · The paper itself

Abstract

Intracranial electrodes are a vital component of implantable neurodevices, both for acute diagnostics and chronic treatment with open and closed-loop neuromodulation. Their performance is hampered by acute implantation trauma and chronic inflammation in response to implanted materials and mechanical mismatch between stiff synthetic electrodes and pulsating, natural soft host neural tissue. Flexible electronics based on thin polymer films patterned with microscale conductive features can help alleviate the mechanically induced trauma; however, this strategy alone does not mitigate inflammation at the device-tissue interface. In this study, we propose a biomimetic approach that integrates microscale extracellular matrix (ECM) coatings on microfabricated flexible subdural microelectrodes. Taking advantage of a high-throughput process employing micro-transfer molding and excimer laser micromachining, we fabricate multi-channel subdural microelectrodes primarily composed of ECM protein material and demonstrate that the electrochemical and mechanical properties match those of standard, uncoated controls. In vivo ECoG recordings in rodent brain confirm that the ECM microelectrode coatings and the protein interface do not alter signal fidelity. Astrogliotic, foreign body reaction to ECM coated devices is reduced, compared to uncoated controls, at 7 and 30 days, after subdural implantation in rat somatosensory cortex. We propose microfabricated, flexible, biomimetic electrodes as a new strategy to reduce inflammation at the device-tissue interface and improve the long-term stability of implantable subdural electrodes.

Indexed as

BiomimeticsElectrodes, ImplantedMicroelectrodesAnimalsCerebral CortexCoated Materials, BiocompatibleElectrocorticographyExtracellular MatrixMicrotechnologyPolymersRatsSubdural SpaceCoated Materials, BiocompatiblePolymers

Identifiers

PMID30383805
PMCPMC6211660
OpenAlexW2899471995

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.