ArticleAnnals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc2019

TWARMI pilot trial: The value and optimal criteria of microvolt T-wave alternans in the diagnosis of reversible myocardial ischemia in patients without structural cardiac disease.

Mislav Puljevic, Ludmila Danilowicz-Szymanowicz, Giulio Molon, Davor Puljevic, Grzegorz Raczak, Guido Canali, Vedran Velagic, Borka Pezo-Nikolic, Davor Milicic

Abstract read
In one paragraph

Article in Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. TWARMI pilot trial: The value and optimal criteria of microvolt T-wave alternans in the diagnosis of reversible myocardial ischemia in patients without structural cardiac disease.Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Mislav PuljevicUniversity of Zagreb, School of Medicine, University Hospital Center Zagreb, Zagreb, Croatia.ORCID 0000-0003-1477-2581
Ludmila Danilowicz-SzymanowiczDepartment of Cardiology and Electrotherapy, Medical University of Gdansk, Gdansk, Poland.
Giulio MolonCardiology Department, S. Cuore Hospital, Verona, Italy.
Davor PuljevicUniversity of Zagreb, School of Medicine, University Hospital Center Zagreb, Zagreb, Croatia.
Grzegorz RaczakDepartment of Cardiology and Electrotherapy, Medical University of Gdansk, Gdansk, Poland.
Guido CanaliCardiology Department, S. Cuore Hospital, Verona, Italy.
Vedran VelagicUniversity of Zagreb, School of Medicine, University Hospital Center Zagreb, Zagreb, Croatia.
Borka Pezo-NikolicUniversity of Zagreb, School of Medicine, University Hospital Center Zagreb, Zagreb, Croatia.
Davor MilicicUniversity of Zagreb, School of Medicine, University Hospital Center Zagreb, Zagreb, Croatia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsMicrovolt T-wave alternans (MTWA) testing is a beat-to-beat fluctuation in the amplitude of T wave. We investigated whether: (a) MTWA can be new non-invasive tool for detection of reversible ischemia in patients with suspected CAD without structural heart disease, (b) MTWA can detect ischemia earlier and with greater test accuracy compared with exercise ECG ST-segment testing, and (c) threshold value of MTWA and heart rate at which the alternans is estimated can be different compared to standard values.

methodsA total of 101 patients with suspected stable coronary disease, but without structural heart disease, were included. Echocardiography, exercise ECG test, MTWA with classical and modified threshold alternans values, and coronary angiography were performed.

resultsAbout 33.3% patients had a false-positive result on exercise ECG test. The sensitivity of exercise ECG ST-segment test in the detection of coronary artery disease was 97.8%, and the specificity was 42.5% (DOR 33.89). In a group of angiographically positive patients, standard MTWA accurately identified 60% of patients, while 40% had a false-negative result. About 91.8% patients with negative angiography result were accurately identified with 8.2% false positives. The sensitivity of MTWA was 59.61% and specificity 91.83%. Best ratio of sensitivity and specificity (86.53% and 95.91%, DOR 151.06) had modified criteria for positive MTWA (MTWA >1.5 µV at heart rate 115-125/min).

conclusionsThis study showed that MTWA can be the new non-invasive tool for the detection of reversible ischemia in patients with suspected CAD without structural heart disease. Also, MTWA can detect ischemia earlier and with greater accuracy compared with exercise ECG testing.

Indexed as

AgedCohort StudiesCoronary AngiographyEchocardiography, DopplerElectrocardiographyExercise TestFemaleHeart RateHumansMaleMiddle AgedMyocardial IschemiaPilot ProjectsProspective StudiesSensitivity and SpecificitySeverity of Illness Indexcoronary artery diseaseexercise ECG testmicrovolt T-wave alternans

Identifiers

PMID30383318
PMCPMC6931817

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.