ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2019
Valgus position of the femoral component causes abnormal kinematics in the presence of medial looseness in total knee arthroplasty: a computer simulation model of TKA for valgus knee osteoarthritis.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Accuracy of a Novel 3D-Printed Patient-Specific Intramedullary Guide to Control Femoral Component Rotation in Total Knee Arthroplasty.Orthopaedic surgery · 2020Trial
- Perioperative combined administration of tranexamic acid and dexamethasone in total knee arthroplasty-benefit versus harm?Medicine · 2019Trial
- Comparable joint awareness and implant survival at midterm follow-up between CR and PS TKA: An anatomic phenotype-based propensity score-matched analysis.Journal of experimental orthopaedics · 2025Article
- Article
- Mismatch between trochlear coronal alignment of arthritic knees and currently available prosthesis: a morphological analysis of 4116 knees and 45 implant designs.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Article
- Excessive flexed position of the femoral component causes abnormal kinematics and joint contact/ ligament forces in total knee arthroplasty.Scientific reports · 2023Article
- Functional Alignment Philosophy in Total Knee Arthroplasty-Rationale and Technique for the Valgus Morphotype Using an Image Based Robotic Platform and Individualized Planning.Journal of personalized medicine · 2023Article
- Biomechanical Effect of Coronal Alignment and Ligament Laxity in Total Knee Arthroplasty: A Simulation Study.Frontiers in bioengineering and biotechnology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTotal knee arthroplasty (TKA) for valgus knee osteoarthritis is challenging. Although overcorrection in TKA for valgus knee osteoarthritis is recommended, supportive data based on biomechanics have rarely been reported. The purpose of this study was to elucidate whether coronal rotation of the femoral compartment causes abnormal kinematics with or without medial looseness.
methodsMulti- and single-radius posterior-stabilised TKA implants were utilised in a computer simulation. A total of 4 mm of slack were provided in the medial collateral ligament (MCL) with varus or valgus position of the femoral component to simulate the context of valgus knee osteoarthritis. Kinematics during gait and squatting activities were evaluated in each condition.
resultsDuring squatting, medial looseness and valgus replacement caused anterior translation of the medial femoral component in mid-flexion in the multi-radius implant. In the worst condition (7° valgus replacement with MCL looseness), there was rapid anterior translation in the multi-radius implant, and moderate anterior translation in the single-radius implant. Although medial looseness alone did not cause abnormal kinematics during gait, the worst condition exhibited an anterior translation to 4.9 mm in the multi-radius implant. This worst condition also exhibited a marked lift-off of 8.0 and 2.9 mm in the multi- and single-radius implants, respectively. Varus position caused little abnormal kinematics even with MCL looseness.
conclusionValgus, not varus position of the femoral component caused abnormal kinematics with MCL looseness. To avoid valgus position, the safety target angle of femoral component would be slight varus rather than neutral in valgus knee OA.
Indexed as
Identifiers
30374567What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.