The impact of variations in input directions according to ISO 14243 on wearing of knee prostheses.

Xiao-Hong Wang, Wei Zhang, Da-Yong Song, Hui Li, Xiang Dong, Min Zhang, Feng Zhao, Zhong-Min Jin, Cheng-Kung Cheng

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 13 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 2 countries.

Xiao-Hong WangSchool of Biological Science and Medical Engineering, Beihang University, Beijing, China.
Wei ZhangBeijing Medical Implant Engineering Research Center, Beijing Naton Technology Group Co.LTD, Beijing, China.
Da-Yong SongBeijing Medical Implant Engineering Research Center, Beijing Naton Technology Group Co.LTD, Beijing, China.
Hui LiBeijing Engineering Laboratory of Functional Medical Materials and Devices, Beijing Naton Technology Group Co.LTD, Beijing, China.
Xiang DongBeijing Engineering Laboratory of Functional Medical Materials and Devices, Beijing Naton Technology Group Co.LTD, Beijing, China.
Min ZhangSchool of Biological Science and Medical Engineering, Beihang University, Beijing, China.
Feng ZhaoSchool of Biological Science and Medical Engineering, Beihang University, Beijing, China.
Zhong-Min JinInstitute of Tribology, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China.
Cheng-Kung ChengSchool of Biological Science and Medical Engineering, Beihang University, Beijing, China.ORCID 0000-0002-2167-6873
Beijing Advanced Sciences and Innovation Center · CNBeihang University · CNUniversity of Leeds · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

ISO 14243 is the governing standard for wear testing of knee prostheses, but there is controversy over the correct direction of anterior-posterior (AP) displacement and loading and the correct direction of tibial rotation (TR) angles and torque. This study aimed to analyze how altering the direction of AP and TR affected wear on the tibial insert. Modifications to the conditions specified in ISO 14243-1 and ISO 14243-3 were also proposed. As such, five loading conditions were applied to FEA models of a knee prosthesis: (1) Modified ISO 14243-3 with positive AP displacement and TR angle, (2) ISO 14243-3:2004 with negative AP displacement and positive TR angle, (3) ISO 14243-3:2014 with positive AP displacement and negative TR angle, (4) Modified ISO 14243-1 with positive AP load and TR torque, and (5) ISO 14243-1:2009 with negative AP load and positive TR torque. This study found that changing the input directions for AP and TR according to ISO 14243-1 and 14243-3 had an influence on the wear rate and wear contours on the tibial insert model. However, the extent of wear varies depending on the design features of the tibial insert and shape of the input curves. For displacement control according to ISO 14243-3, changing the direction of AP displacement had a marked influence on the wear rate (272.77%), but changing the direction of TR angle had a much lower impact (2.17%). For load control according to ISO 14243-1, reversing the AP load (ISO 14243-1:2009) only increased the wear rate by 6.73% in comparison to the modified ISO 14243-1 conditions. The clinical relevance of this study is that the results demonstrate that tibial wear is affected by the direction of application of AP and TR. Incorrect application of the loading conditions during the design stage may lead to an ineffective preclinical evaluation and could subsequently influence implant longevity in clinical use.

Indexed as

Arthroplasty, Replacement, KneeBiomechanical PhenomenaGaitHumansKnee ProsthesisProsthesis FailureRange of Motion, ArticularTorqueWeight-Bearing