ArticleMedical physics2019
Estimating the spectrum in computed tomography via Kullback-Leibler divergence constrained optimization.
Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Accurate volume image reconstruction for digital breast tomosynthesis with directional-gradient and pixel sparsity regularization.Journal of medical imaging (Bellingham, Wash.) · 2025Article
- MISD-IR: material-image subspace decomposition-based iterative reconstruction with spectrum estimation for dual-energy computed tomography.Quantitative imaging in medicine and surgery · 2024Article
- Spectral calibration of photon-counting detectors at high photon flux.Medical physics · 2022Article
- Addressing CT metal artifacts using photon-counting detectors and one-step spectral CT image reconstruction.Medical physics · 2022Article
- Physical density estimations of single- and dual-energy CT using material-based forward projection algorithm: a simulation study.The British journal of radiology · 2021Article
- Invertibility of multi-energy X-ray transform.Medical physics · 2021Article
- Image-domain Material Decomposition for Spectral CT using a Generalized Dictionary Learning.IEEE transactions on radiation and plasma medical sciences · 2021Article
- Semiempirical, parameterized spectrum estimation for x-ray computed tomography.Medical physics · 2021Article
- Erratum: Estimating the spectrum in computed tomography via Kullback-Leibler divergence constrained optimization. [Med. Phys. 46(1), p. 81-92 (2019)].Medical physics · 2020Article
- Application value of dual-energy computed tomography spectrum curve combined with clinical risk factors in predicting adherent perinephric fat.Quantitative imaging in medicine and surgery · 2019Article
Corrections and comments
- Erratum issued
Authors and funding
5 authors.
Funding
Abstract
purposeWe study the problem of spectrum estimation from transmission data of a known phantom. The goal is to reconstruct an x-ray spectrum that can accurately model the x-ray transmission curves and reflects a realistic shape of the typical energy spectra of the CT system.
methodsSpectrum estimation is posed as an optimization problem with x-ray spectrum as unknown variables, and a Kullback-Leibler (KL)-divergence constraint is employed to incorporate prior knowledge of the spectrum and enhance numerical stability of the estimation process. The formulated constrained optimization problem is convex and can be solved efficiently by use of the exponentiated-gradient (EG) algorithm. We demonstrate the effectiveness of the proposed approach on the simulated and experimental data. The comparison to the expectation-maximization (EM) method is also discussed.
resultsIn simulations, the proposed algorithm is seen to yield x-ray spectra that closely match the ground truth and represent the attenuation process of x-ray photons in materials, both included and not included in the estimation process. In experiments, the calculated transmission curve is in good agreement with the measured transmission curve, and the estimated spectra exhibits physically realistic looking shapes. The results further show the comparable performance between the proposed optimization-based approach and EM.
conclusionsOur formulation of a constrained optimization provides an interpretable and flexible framework for spectrum estimation. Moreover, a KL-divergence constraint can include a prior spectrum and appears to capture important features of x-ray spectrum, allowing accurate and robust estimation of x-ray spectrum in CT imaging.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.