ArticleJAMA network open2018
Analysis of Errors in Dictated Clinical Documents Assisted by Speech Recognition Software and Professional Transcriptionists.
Article in JAMA network open, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 47 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
47 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Evaluating the performance of artificial intelligence-based speech recognition for clinical documentation: a systematic review.BMC medical informatics and decision making · 2025Pooled it
- Speech recognition for clinical documentation from 1990 to 2018: a systematic review.Journal of the American Medical Informatics Association : JAMIA · 2019Pooled it
- AI for Health Care Quality and Patient Safety: Scoping Review of Diagnostic, Predictive, and Decision Support Applications.Journal of medical Internet research · 2026Article
- For the record: a narrative review of ambient voice technology in clinical documentation for dentistry and wider healthcare.British dental journal · 2026Review
- Reporting efficiency in diagnostic imaging: Can plug-and-play general-purpose large language models outperform conventional speech recognition?European radiology · 2026Article
- Feasibility of Tailoring Artificial Intelligence-Assisted Ambient Scribes for Intensive Care Unit Rounds: Algorithm Development and Validation.JMIR medical informatics · 2026Article
- Reasoning Model-Assisted Second-Reader Quality Control of Chinese-Language Ultrasound Reports: A Retrospective Imaging Informatics Study.Journal of imaging informatics in medicine · 2026Article
- Ambient AI Scribe Implementation in an Ambulatory Setting in a Single Medical Group: Prospective Study.JMIR medical informatics · 2026Article
- Assessing the Reliability, Accuracy, and Relevance of Artificial Intelligence Speech Recognition for Clinical Documentation: A Scoping Review.Journal of evaluation in clinical practice · 2026Article
- Large language model-based scribing tools for ophthalmology: performance and safety evaluation using simulated clinical encounters.Eye (London, England) · 2026Article
- Automatic Speech Recognition and Large Language Models for Multilingual Pathology Report Generation: Proof-of-Concept Study.JMIR formative research · 2026Article
- AI-generated clinical summaries: errors and susceptibility to speech and speaker variability.BMJ health & care informatics · 2026Article
- Article
- Accuracy of large language model transcription of simulated physician-patient verbal interactions.BMC medical informatics and decision making · 2026Article
- Ethical considerations for clinical adoption of ambient digital scribe technology.Journal of the American Medical Informatics Association : JAMIA · 2026Article
- Implementation of Ambient AI Scribes in Hospitals: Lessons for Healthcare Leadership, Governance, and Change Management.Journal of healthcare leadership · 2026Review
- Evaluating the Quality and Safety of Ambient Digital Scribe Platforms Using Simulated Ambulatory Encounters.Mayo Clinic proceedings. Digital health · 2025Article
- Large language models for error detection in radiology reports: a comparative analysis between closed-source and privacy-compliant open-source models.European radiology · 2025Article
- Speech Recognition Technology and Documentation Efficiency.JAMA network open · 2025Article
- Evaluating the Application of Artificial Intelligence and Ambient Listening to Generate Medical Notes in Vitreoretinal Clinic Encounters.Clinical ophthalmology (Auckland, N.Z.) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
importanceAccurate clinical documentation is critical to health care quality and safety. Dictation services supported by speech recognition (SR) technology and professional medical transcriptionists are widely used by US clinicians. However, the quality of SR-assisted documentation has not been thoroughly studied.
objectiveTo identify and analyze errors at each stage of the SR-assisted dictation process. DESIGN SETTING AND
participantsThis cross-sectional study collected a stratified random sample of 217 notes (83 office notes, 75 discharge summaries, and 59 operative notes) dictated by 144 physicians between January 1 and December 31, 2016, at 2 health care organizations using Dragon Medical 360 | eScription (Nuance). Errors were annotated in the SR engine-generated document (SR), the medical transcriptionist-edited document (MT), and the physician's signed note (SN). Each document was compared with a criterion standard created from the original audio recordings and medical record review. MAIN OUTCOMES AND MEASURES: Error rate; mean errors per document; error frequency by general type (eg, deletion), semantic type (eg, medication), and clinical significance; and variations by physician characteristics, note type, and institution.
resultsAmong the 217 notes, there were 144 unique dictating physicians: 44 female (30.6%) and 10 unknown sex (6.9%). Mean (SD) physician age was 52 (12.5) years (median [range] age, 54 [28-80] years). Among 121 physicians for whom specialty information was available (84.0%), 35 specialties were represented, including 45 surgeons (37.2%), 30 internists (24.8%), and 46 others (38.0%). The error rate in SR notes was 7.4% (ie, 7.4 errors per 100 words). It decreased to 0.4% after transcriptionist review and 0.3% in SNs. Overall, 96.3% of SR notes, 58.1% of MT notes, and 42.4% of SNs contained errors. Deletions were most common (34.7%), then insertions (27.0%). Among errors at the SR, MT, and SN stages, 15.8%, 26.9%, and 25.9%, respectively, involved clinical information, and 5.7%, 8.9%, and 6.4%, respectively, were clinically significant. Discharge summaries had higher mean SR error rates than other types (8.9% vs 6.6%; difference, 2.3%; 95% CI, 1.0%-3.6%; CONCLUSIONS AND RELEVANCE: Seven in 100 words in SR-generated documents contain errors; many errors involve clinical information. That most errors are corrected before notes are signed demonstrates the importance of manual review, quality assurance, and auditing.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.