Evidence map›Paper›PMID 30367254›Full record

ArticleArchives of orthopaedic and trauma surgery2018

Cemented conical stems can be removed more easily than cylindrical stems, regardless of cone angle in revision knee arthroplasty.

Alexander Maslaris, Frank Layher, Olaf Brinkmann, Matthias Bungartz, Timo Zippelius, Georg Matziolis

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.2field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Alexander MaslarisDepartment of Orthopedics, Friedrich-Schiller-University of Jena, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany. alexander_maslaris@hotmail.com.
Frank LayherDepartment of Orthopedics, Laboratory of Biomechanics, Friedrich-Schiller-University of Jena, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.
Olaf BrinkmannDepartment of Orthopedics, Friedrich-Schiller-University of Jena, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.
Matthias BungartzDepartment of Orthopedics, Friedrich-Schiller-University of Jena, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.
Timo ZippeliusDepartment of Orthopedics, Friedrich-Schiller-University of Jena, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.
Georg MatziolisDepartment of Orthopedics, Friedrich-Schiller-University of Jena, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.
Waldkrankenhaus Rudolf Elle · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAccording to literature, more than 30% of revised knee arthroplasties will require at least one re-revision. Practical experience has shown that there are considerable product-specific differences in the explantability of cemented long-stem prostheses. In the registers of successful implants, stem geometry varies considerably between the manufacturers. However, comparative data on explantability of the respective stems are missing. Objective of the present study was to identify a correlation between the geometry of a smooth cemented long stem and the necessary explantation energy required until failure of the implant-cement interface occurs.

methodsEight cemented stems with different conical profile angles (0°-3°) were explanted in a reproducible biomechanical setup each six times to evaluate the correlation between the stem design and the required explantation energy.

resultsThe average explantation energy was highest in the case of the cylindrical stem, at 18.1 ± 3.6 J. At a cone angle of 0.25°, it was just 12.1 ± 2.1 J (p < 0.001) and dropped beyond 0.5° to an average of 5.7 ± 1.8 J (p < 0.001). Between 0.5° and 3°, no significant difference in the required extraction energy was observed.

conclusionsWhereas smooth conical stems can mostly be removed easily, an early decision in favour of osteotomy or fenestration can be taken in the case of cylindrical cemented stems.

Indexed as

Arthroplasty, Replacement, KneeBone CementsHumansKnee ProsthesisProsthesis DesignProsthesis FailureReoperationBone CementsConical stemsExplantation cemented stemsImplant removalStem designSurgical complicationsTotal knee arthroplasty revision

Identifiers

PMID30367254
OpenAlexW2898159781

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked