Evidence map›Paper›PMID 30361274›Full record

ReviewThe British journal of ophthalmology2019

Ultrasonic measurement of optic nerve sheath diameter: a non-invasive surrogate approach for dynamic, real-time evaluation of intracranial pressure.

Li-Min Chen, Li-Juan Wang, Yang Hu, Xiao-Han Jiang, Yu-Zhi Wang, Ying-Qi Xing

Registry-linked trialAbstract readReview
In one paragraph

Review in The British journal of ophthalmology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05195801 (Intraoperative Optic Nerve Diameter and Intraocular Pressure Changes in Patients Undergoing Vitrectomy), which is not on this map. Cited by 59 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
59citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05195801 unknown statusnot on this mapstarted 2022, after this paper: background citation

Intraoperative Optic Nerve Diameter and Intraocular Pressure Changes in Patients Undergoing Vitrectomy (PPV) Surgery Under General Anesthesia and Their Effects on Vision in the Postoperative Period

TypeobservationalSponsorAkdeniz UniversityRan2022 to 2024Enrolled60ConditionsVision Disorders, Ocular Surface DiseaseArmsUSG
3 · Its place in the literature

Who cites it

59 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Intraindividual Optic Nerve Sheath Variation and Intracranial Pressure Changes: A Systematic Review and Meta-Analysis.Journal of neuroimaging : official journal of the American Society of Neuroimaging
    Pooled it
  2. Trial
  3. Trial
  4. Observational
  5. Article
  6. Observational
  7. Article
  8. Article
  9. Review
  10. Review
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Li-Min Chen *Department of Neurology and Neuroscience Center, The First Hospital of Jilin University, Changchun, China.
Li-Juan Wang *Department of Neurology and Neuroscience Center, The First Hospital of Jilin University, Changchun, China.
Yang HuDepartment of Neurology and Neuroscience Center, The First Hospital of Jilin University, Changchun, China.
Xiao-Han JiangDepartment of Neurology and Neuroscience Center, The First Hospital of Jilin University, Changchun, China.
Yu-Zhi WangDepartment of Neurology and Neuroscience Center, The First Hospital of Jilin University, Changchun, China.
Ying-Qi XingDepartment of Neurology and Neuroscience Center, The First Hospital of Jilin University, Changchun, China xingyq2009@sina.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The current study aimed to identify whether ultrasonographic measurements of optic nerve sheath diameter (ONSD) could dynamically and sensitively evaluate real-time intracranial pressure (ICP). ONSD measurements were performed approximately 5  min prior to and after a lumbar puncture (LP). A total of 84 patients (mean±SD age, 43.5±14.7 years; 41 (49%) men; 18 patients with elevated ICP) were included in the study. The Spearman correlation coefficients between the two observers were 0.779 and 0.703 in the transverse section and 0.751 and 0.788 in the vertical section for the left and right eyes, respectively. The median (IQR) change in ONSD (ΔONSD) and change in ICP (ΔICP) were 0.11 (0.05-0.21) mm and 30 (20-40) mmH

Indexed as

AdolescentAdultAgedAged, 80 and overFemaleHumansIntracranial PressureMaleMiddle AgedOptic NerveProspective StudiesROC CurveSpinal PunctureUltrasonographyYoung Adultintracranial pressurelumbar punctureoptic nerveultrasonic measurement

Identifiers

PMID30361274
PMCPMC6691934

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.