Evidence map›Paper›PMID 30356404›Full record

ArticleBioMed research international2018

Comparison and Noise Suppression of the Transmitted and Reflected Photoplethysmography Signals.

Suyi Li, Lijia Liu, Jiang Wu, Bingyi Tang, Dongsheng Li

Abstract read
In one paragraph

Article in BioMed research international, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Review
  14. A Pulse Signal Preprocessing Method Based on the Chauvenet Criterion.Computational and mathematical methods in medicine · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Suyi LiCollege of Instrumentation and Electrical Engineering, Jilin University, Changchun, China.ORCID 0000-0003-3599-2102
Lijia LiuCollege of Instrumentation and Electrical Engineering, Jilin University, Changchun, China.ORCID 0000-0002-8878-8968
Jiang WuCollege of Instrumentation and Electrical Engineering, Jilin University, Changchun, China.ORCID 0000-0002-9136-5069
Bingyi TangCollege of Instrumentation and Electrical Engineering, Jilin University, Changchun, China.ORCID 0000-0003-4279-098X
Dongsheng LiNational Geophysical Exploration Equipment Engineering Research Center, Jilin University, Changchun, China.ORCID 0000-0003-0008-6687

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The photoplethysmography (PPG) is inevitably corrupted by many kinds of noise no matter whether its acquisition mode is transmittance or reflectance. To enhance the quality of PPG signals, many studies have made great progress in PPG denoising by adding extra sensors and developing complex algorithms. Considering the reasonable cost, compact size, and real-time and easy implementation, this study proposed a simple real-time denoising method based on double median filters which can be integrated in microcontroller of commercial or portable pulse oximeters without adding extra hardware. First, we used the boundary extension to preserve the signal boundary distortion and designed a first median filter with the time window at approximately 78 ms to eliminate the high-frequency components of the signal. Then, through the second median filter with a time window which was about 780 ms, we estimated the low-frequency components. Finally, we removed the estimated low-frequency components from the signal to obtain the denoised signal. Through comparing the multiple sets of signals under calmly sitting and slightly moving postures, the PPG signals contained noises no matter whether collected by the transmittance-mode or the reflectance-mode. To evaluate the proposed method, we conducted measured, simulated experiments and a strong noisy environment experiment. Through comparing the morphology distortions, frequency spectra, and the signal-to-noise ratios (SNRs), the results showed that the proposed method can suppress noise effectively and preserve the essential morphological features from PPG signals. As a result, the proposed method can enhance the quality of PPG signals and, thus, can contribute to the improvement of the calculation accuracy of the subsequent physiological parameters. In addition, the proposed method could be a good choice to address the real-time noise reduction of portable PPG measuring instruments.

Indexed as

AlgorithmsArtifactsPhotoplethysmographySignal Processing, Computer-AssistedSignal-To-Noise Ratio

Identifiers

PMID30356404
PMCPMC6178150

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.