ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2020
Comparison of intraoperative 2D vs. 3D imaging in open reduction and fixation of distal radius fractures.
Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- "Is the effect of intraoperative 3D imaging beneficial in plate fixation of distal radius fractures: a matched-pair analysis".European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026Article
- Skyline view versus intraoperative 3D fluoroscopy for dorsal screw protrusion identification following volar plating in the treatment of distal radial fracture.Journal of orthopaedic surgery and research · 2025Article
- INTRAOPERATIVE COMPUTED TOMOGRAPHY: AN ADVANCED APPROACH FOR VISUALIZATION OF FIXATION MATERIAL IN DISTAL RADIUS FRACTURES.Acta ortopedica brasileira · 2025Article
- Image Quality Comparison of Three 3D Mobile X-Ray Imaging Guidance Devices Used in Spine Surgery: A Phantom Study.Sensors (Basel, Switzerland) · 2024Article
- Comparison of a ceiling-mounted 3D flat panel detector vs. conventional intraoperative 2D fluoroscopy in plate osteosynthesis of distal radius fractures with volar locking plate systems.BMC musculoskeletal disorders · 2021Article
- Intraoperative 3D imaging in intraarticular tibial plateau fractures - Does it help to improve the patients' outcomes?Journal of orthopaedic surgery and research · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeIn the volar plating of distal radius fractures, intraoperative three-dimensional (3D) imaging is designed to allow better judgment regarding screw and implant positioning compared with conventional intraoperative two-dimensional (2D) imaging. We evaluated the impact of these two imaging modalities on the rates of intraoperative revision and secondary surgery, as well as the need for implant removal during follow-up.
methodsA retrospective analysis of consecutive patients who underwent volar plate osteosynthesis for isolated distal radius fractures between January 2008 and April 2016 was performed. Patient files were evaluated for intraoperative imaging findings, intraoperative and postoperative revision rates, and implant removal during follow-up. Additional analyses of radiation exposure, operation time, and hospitalization time were performed.
resultsA total of 314 patients were analyzed (mean age: 54 ± 19 years; 210 females). For 246 patients, only 2D imaging was performed, while the remaining 68 patients underwent both 2D and 3D imaging (O-Arm, Medtronic). The intraoperative revision rate was significantly (p < 0.001) higher with 3D imaging (32.4%) compared with 2D imaging (2.0%). The postoperative revision rates were similar between both the groups (2.9% vs. 2.0%; p = 0.674). Compared with 2D imaging, the use of the Medtronic O-Arm resulted in a significantly lower implant removal rate (8.8% vs. 18.7%; p = 0.036) during follow-up.
conclusionCompared with conventional 2D imaging, the use of intraoperative 3D imaging significantly increased the intraoperative revision rate and has the potential for positive long-term effects for lowering the risk of requiring an implant removal.
Indexed as
Identifiers
30350005What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.