Evidence map›Paper›PMID 30344396›Full record

ArticleJournal of maxillofacial and oral surgery2018

Effect of Milliamperage Reduction on Pre-surgical Implant Planning Using Cone Beam Computed Tomography by Surgeons of Varying Experience.

N El Sahili, S David-Tchouda, S Thoret, I Nasseh, A Berberi, T Fortin

Abstract read
In one paragraph

Article in Journal of maxillofacial and oral surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

N El Sahili1School of Dentistry, Lebanese University, Beirut, Lebanon.
S David-Tchouda2Medico-economic Evaluation Unit, University Hospital of Grenoble, France/ThEMAS TIMC, UMR CNRS 5525, Grenoble Joseph Fourier University, Grenoble, France.
S Thoret3Investigation Clinical Center of Grenoble, INSERM, Grenoble, France.
I Nasseh4Department of Oral and Maxillofacial Surgery, School of Dentistry, Lebanese University, Beirut, Lebanon.
A Berberi5Department of Oral and MaxilloFaciale Surgery, School of Dentistry, Lebanese University, Beirut, Lebanon.
T Fortin6Department of Oral Surgery, Dental University of Lyon, University Claude Bernard, Lyon 1, France. UJF-Grenoble 1/CNRS/TIMC-IMAG UMR 5525, 38041 Grenoble, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDifferences in CBCT units and the lack of standardization result in exposure to radiation doses beyond what is required for diagnostic purposes, especially when planning the surgical placement of dental implants.

aimTo assess the influence of low- and high-dose milliamperage settings on CBCT images for objective and subjective implant planning among senior specialists (5 years of experience) and juniors (fresh graduates). MATERIALS AND

methodsTwo dry skulls (4 hemi-maxillary segments of the maxilla and 4 hemi-maxillary segments of the mandible) were scanned under low (2 mA) and high (6.3 mA) dosage settings using the Carestream CS 9300 machine. Cross-sectional slices of both image qualities were evaluated by the 5 seniors and the 5 juniors for subjective image utility for implant planning and for objective linear bone measurements.

resultsThere were no significant differences in bone measurements taken on high- or low-dose images by all seniors and by the majority of juniors (

conclusionReduction in milliamperage did not affect diagnostic image quality for objective bone measurements and produced sufficient concordance for qualitative assessment. Judicious optimization of milliamperage settings based on individual diagnostic requirements can result in significant dose reduction without compromising diagnostic decision-making.

Indexed as

Cone beam computed tomographyImage resolutionImplant-placement planningRadiation dose alteration

Identifiers

PMID30344396
PMCPMC6181865

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked