Evidence map›Paper›PMID 30344373›Full record

ArticleSensors and actuators. B, Chemical2019

Monolithic CMOS sensor platform featuring an array of 9'216 carbon-nanotube-sensor elements and low-noise, wide-bandwidth and wide-dynamic-range readout circuitry.

Alexandra Dudina, Florent Seichepine, Yihui Chen, Alexander Stettler, Andreas Hierlemann, Urs Frey

Abstract read
In one paragraph

Article in Sensors and actuators. B, Chemical, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Alexandra DudinaETH Zurich, Bio Engineering Laboratory, Department of Biosystems Science and Engineering, Basel, Switzerland.
Florent SeichepineRIKEN QBiC, Kobe, Japan.
Yihui ChenAnalog Devices Shanghai Co. Ltd., Shanghai, China.
Alexander StettlerETH Zurich, Bio Engineering Laboratory, Department of Biosystems Science and Engineering, Basel, Switzerland.
Andreas HierlemannETH Zurich, Bio Engineering Laboratory, Department of Biosystems Science and Engineering, Basel, Switzerland.
Urs FreyETH Zurich, Bio Engineering Laboratory, Department of Biosystems Science and Engineering, Basel, Switzerland.

Funding

European Research Council 267351European Research Council 694829
6 · The paper itself

Abstract

We present the design and characterization of a monolithic complementary metal-oxide-semiconductor (CMOS) biosensor platform comprising of a switch-matrix-based array of 9'216 carbon nanotube field-effect transistors (CNTFETs) and associated readout circuitry. The switch-matrix allows for flexible selection and simultaneous routing of 96 sensor elements to the corresponding readout channels. A low-noise, wide-bandwidth, wide-dynamic-range transimpedance continuous-time amplifier architecture has been implemented to facilitate resistance measurements in the range between 50 kΩ and 1 GΩ at a bandwidth of up to 1 MHz. The achieved accuracy of the resistance measurements over the whole range is 4%. The system has been successfully fabricated and tested and shows a noise performance equal to 2.14 pA

Indexed as

Carbon nanotube field-effect transistorChemFETCMOSIon-sensitive field-effect transistors

Identifiers

PMID30344373
PMCPMC6193531

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.