Evidence map›Paper›PMID 30343642›Full record

ArticleTechnology in cancer research & treatment2018

Feasibility of a Skin Dose Reduction for Nasopharyngeal Carcinoma Treated With High-Intensity-Modulated Delivery Techniques.

Xiongfei Liao, Jie Li, Pei Wang, Xinghong Yao, Yulei Zhang, Tingqiang Tan, Lucia Clara Orlandini

Open access · goldAbstract read
In one paragraph

Article in Technology in cancer research & treatment, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 81% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Xiongfei Liao1 Department of Radiation Oncology, Sichuan Cancer Hospital & Research Institute, Chengdu, China.
Jie Li1 Department of Radiation Oncology, Sichuan Cancer Hospital & Research Institute, Chengdu, China.ORCID 0000-0001-7163-3778
Pei Wang1 Department of Radiation Oncology, Sichuan Cancer Hospital & Research Institute, Chengdu, China.
Xinghong Yao1 Department of Radiation Oncology, Sichuan Cancer Hospital & Research Institute, Chengdu, China.
Yulei Zhang1 Department of Radiation Oncology, Sichuan Cancer Hospital & Research Institute, Chengdu, China.
Tingqiang Tan1 Department of Radiation Oncology, Sichuan Cancer Hospital & Research Institute, Chengdu, China.
Lucia Clara Orlandini1 Department of Radiation Oncology, Sichuan Cancer Hospital & Research Institute, Chengdu, China.
Sichuan Cancer Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Acute skin toxicity observed in radiotherapy treatment of head and neck cancer is a big concern. The purpose of this work is to evaluate the feasibility of a skin dose reduction in the treatment of nasopharyngeal carcinoma without compromising the overall plan quality. This research focused on comparison of the skin dose reduction that can be obtained for the main high conformal radiotherapy delivery techniques. Sixteen cases of early-stage nasopharyngeal carcinoma were included in this study. For each case, a dynamic intensity-modulated radiation therapy, a volumetric modulated arc therapy, and a helical tomotherapy treatment plans were performed with and without the skin as a sensitive structure in the inverse plan optimization. The dosimetric results obtained for the different treatment techniques and plan optimizations were compared. Dose-volume histogram cutoff points of D95%, D98%, and the homogeneity index were used for target comparison, while Dmean and Dmax/D1cc were used for the organs at risk. The skin volume receiving 5 Gy and then 10 to 70 Gy of radiation dosage registered at step of 10 Gy and Dmean were used for the skin dose comparison. One-way analysis of variance was used to assess the dosimetric results obtained for the different types of treatment plans and techniques investigated. A total of 96 treatment plans were analyzed. When the neck skin was considered in the treatment optimization process, the skin volume that received more than 30 Gy was reduced by 3.7% for dynamic intensity modulated, 4.1% for volumetric modulated arc, and 4.3% for dynamic intensity modulated, while the target dose coverage and organs at risk dosages remained unvaried ( p > .05).

Indexed as

Organs at RiskRadiotherapy, Intensity-ModulatedHumansNasopharyngeal CarcinomaNasopharyngeal NeoplasmsNeoplasm StagingRadiation InjuriesRadiometryRadiotherapy DosageSkinintensity-modulated radiation therapynasopharyngeal carcinomaskin dosetomotherapyvolumetric modulated radiation therapy

Identifiers

PMID30343642
PMCPMC6198397
OpenAlexW2897787952

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.