Evidence map›Paper›PMID 30342288›Full record

ArticleActa biomaterialia2018

Effect of working environment and procedural strategies on mechanical performance of bioresorbable vascular scaffolds.

Pei-Jiang Wang, Farhad Rikhtegar Nezami, Maysam B Gorji, Francesca Berti, Lorenza Petrini, Tomasz Wierzbicki, Francesco Migliavacca, Elazer R Edelman

Open access · greenAbstract read
In one paragraph

Article in Acta biomaterialia, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
3.3field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 32 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 2 countries.

Pei-Jiang WangBiomedical Engineering Center, Institute for Medical Engineering & Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA. Electronic address: wpj@mit.edu.
Farhad Rikhtegar NezamiBiomedical Engineering Center, Institute for Medical Engineering & Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA. Electronic address: farhadr@mit.edu.
Maysam B GorjiImpact and Crashworthiness Laboratory, Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA. Electronic address: gorji@mit.edu.
Francesca BertiBiomedical Engineering Center, Institute for Medical Engineering & Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Milano, Italy. Electronic address: fberti@mit.edu.
Lorenza PetriniDepartment of Civil and Environmental Engineering, Politecnico di Milano, Milano, Italy. Electronic address: lorenza.petrini@polimi.it.
Tomasz WierzbickiImpact and Crashworthiness Laboratory, Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA. Electronic address: wierz@mit.edu.
Francesco MigliavaccaLaboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Milano, Italy. Electronic address: francesco.migliavacca@polimi.it.
Elazer R EdelmanBiomedical Engineering Center, Institute for Medical Engineering & Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Cardiovascular Division, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA. Electronic address: ere@mit.edu.
Impact Technology Development (United States) · USMassachusetts Institute of Technology · USPolitecnico di Milano · ITBoston University · USBrigham and Women's Hospital · US

Funding

Vascular Drug Delivery - Supplement for EquipmentR01GM049039 · NIGMS · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI EDELMAN, ELAZER R · 1994 to 2019
$8.9M
NIGMS NIH HHS R01 GM049039
6 · The paper itself

Abstract

Polymeric bioresorbable scaffolds (BRS), at their early stages of invention, were considered as a promising revolution in interventional cardiology. However, they failed dramatically compared to metal stents showing substantially higher incidence of device failure and clinical events, especially thrombosis. One problem is that use of paradigms inherited from metal stents ignores dependency of polymer material properties on working environment and manufacturing/deployment steps. Unlike metals, polymeric material characterization experiments cannot be considered identical under dry and submerged conditions at varying rates of operation. We demonstrated different material behaviors associated with variable testing environment and parameters. We, then, have employed extracted material models, which are verified by computational methods, to assess the performance of a full-scale BRS in different working condition and under varying procedural strategies. Our results confirm the accepted notion that slower rate of crimping and inflation can potentially reduce stress concentrations and thus reduce localized damages. However, we reveal that using a universal set of material properties derived from a benchtop experiment conducted regardless of working environment and procedural variability may lead to a significant error in estimation of stress-induced damages and overestimation of benefits procedural updates might offer. We conclude that, for polymeric devices, microstructural damages and localized loss of structural integrity should complement former macroscopic performance-assessment measures (fracture and recoil). Though, to precisely capture localized stress concentration and microstructural damages, context-related testing environment and clinically-relevant procedural scenarios should be devised in preliminary experiments of polymeric resorbable devices to enhance their efficacy and avoid unpredicted clinical events. STATEMENT OF SIGNIFICANCE: Bioresorbable scaffolds (BRS) with the hope to become the next cardiovascular interventional revolution failed in comparison to metal stents. When BRS were characterized using methods for metal stents, designers were misled to seek problem sources at erroneous timeframe and use inefficient indicators, and thus no signal of concern emerged. We demonstrated fundamental flaws associated with applying a universal set of material properties to study device performances in different phases of manufacturing/implantation, and these may be responsible for failure in predicting performance in first-generation BRS. We introduced new criterion for the assessment of structural integrity and device efficacy in next-generation BRS, and indeed all devices using polymeric materials which evolve with the environment they reside in.

Indexed as

Absorbable ImplantsBlood Vessel ProsthesisProsthesis DesignStentsHumansTissue ScaffoldsBioresorbable scaffoldsFinite element analysisMicrostructural damagesPolymer characterizationWorking environment

Identifiers

PMID30342288
PMCPMC6295666
OpenAlexW2897287626

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.