Evidence map›Paper›PMID 30342106›Full record

ArticleJournal of neuroscience methods2019

An open-source control system for in vivo fluorescence measurements from deep-brain structures.

Scott F Owen, Anatol C Kreitzer

Abstract read
In one paragraph

Article in Journal of neuroscience methods, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
0.9field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Scott F OwenGladstone Institutes, United States. Electronic address: scott.owen@gladstone.ucsf.edu.
Anatol C KreitzerGladstone Institutes, United States; Department of Neurology, UCSF, United states; Kavli Institute for Fundamental Neuroscience, United States; UCSF Weill Institute for Neurosciences, United States; Department of Physiology, UCSF, United States.
Gladstone Institutes · US

Funding

Striatal Microcircuits: Regulation and FunctionR01NS078435 · NINDS · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI BERKE, JOSHUA D, KREITZER, ANATOL · 2012 to 2016
$2.4M
EXTRAMULAR RESEARCH FACILITIES CONSTRUCTIONC06RR018928 · NCRR · J. DAVID GLADSTONE INSTITUTES · PI MAHLEY, ROBERT W. · 2003 to 2003
$2.1M
Modulatory control of basal ganglia microcircuitry in cognitive flexibility and psychiatric diseaseK99MH110597 · NIMH · J. DAVID GLADSTONE INSTITUTES · PI OWEN, SCOTT · 2016 to 2017
$256k
Inhibitory microcircuitry coordinates striatal functionF32NS083369 · NINDS · J. DAVID GLADSTONE INSTITUTES · PI OWEN, SCOTT · 2014 to 2016
$126k
NCRR NIH HHS C06 RR018928NIMH NIH HHS K99 MH110597NINDS NIH HHS F32 NS083369NINDS NIH HHS R01 NS078435
6 · The paper itself

Abstract

backgroundIntracranial photometry through chronically implanted optical fibers is a widely adopted technique for measuring signals from fluorescent probes in deep-brain structures. The recent proliferation of bright, photo-stable, and specific genetically encoded fluorescent reporters for calcium and for other neuromodulators has greatly increased the utility and popularity of this technique. NEW

methodHere we describe an open-source, cost-effective, microcontroller-based solution for controlling optical components in an intracranial photometry system and processing the resulting signal.

resultsWe show proof-of-principle that this system supports high quality intracranial photometry recordings from dorsal striatum in freely moving mice. A single system supports simultaneous fluorescence measurements in two independent color channels, but multiple systems can be integrated together if additional fluorescence channels are required. This system is designed to work in combination with either commercially available or custom-built optical components. Parts can be purchased for less than one tenth the cost of commercially available alternatives and complete assembly takes less than one day for an inexperienced user. COMPARISON WITH EXISTING METHOD(S): Currently available hardware draws on a variety of commercial, custom-built, or hybrid elements for both optical and electronic components. Many of these hardware systems are either specialized and inflexible, or over-engineered and expensive.

conclusionsThis open-source system increases experimental flexibility while reducing cost relative to current commercially available components. All software and firmware are open-source and customizable, affording a degree of experimental flexibility that is not available in current commercial systems.

Indexed as

AnimalsCalcium SignalingCorpus StriatumEquipment DesignFluorometryMiceOptical FibersOptical ImagingSoftwareBasal gangliaBiophotonicsFluorescenceGCaMPMicrocontrollersOpen-SourceOptical fibersPhotometry

Identifiers

PMID30342106
PMCPMC6258340
OpenAlexW2949265294

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.