Evidence map›Paper›PMID 30341652›Full record

ArticleSurgical endoscopy2019

Indocyanine green fluorescence-guided laparoscopic surgery, with omental appendices as fluorescent markers for colorectal cancer resection: a pilot study.

Atsushi Hamabe, Takayuki Ogino, Tsukasa Tanida, Shingo Noura, Shunji Morita, Keizo Dono

Abstract read
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.4field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Atsushi HamabeDepartment of Surgery, Toyonaka Municipal Hospital, 4-14-1 Shibahara-cho, Toyonaka, Osaka, 560-8565, Japan. ahamabe1981@gmail.com.ORCID http://orcid.org/0000-0001-5535-3514
Takayuki OginoDepartment of Surgery, Toyonaka Municipal Hospital, 4-14-1 Shibahara-cho, Toyonaka, Osaka, 560-8565, Japan.
Tsukasa TanidaDepartment of Surgery, Toyonaka Municipal Hospital, 4-14-1 Shibahara-cho, Toyonaka, Osaka, 560-8565, Japan.
Shingo NouraDepartment of Surgery, Toyonaka Municipal Hospital, 4-14-1 Shibahara-cho, Toyonaka, Osaka, 560-8565, Japan.
Shunji MoritaDepartment of Surgery, Toyonaka Municipal Hospital, 4-14-1 Shibahara-cho, Toyonaka, Osaka, 560-8565, Japan.
Keizo DonoDepartment of Surgery, Toyonaka Municipal Hospital, 4-14-1 Shibahara-cho, Toyonaka, Osaka, 560-8565, Japan.
Toyonaka Municipal Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCurrently, we lack tools that can reliably guide laparoscopic surgeons to a target anatomical destination for dissection. We aimed to develop and evaluate a fluorescent destination marker (FDM), composed of a resected omental appendix injected with indocyanine green (ICG), for real-time navigation in laparoscopic surgery for colorectal cancer in this pilot study.

methodsThis study included ten patients diagnosed with colorectal cancer. To prepare FDMs, we laparoscopically harvested omental appendices attached to the colon we planned to resect. The harvested appendices were injected with diluted ICG, and a gauze tag was attached. The FDMs were placed at target intra-abdominal sites with a ligation clip.

resultsPatient diagnoses included 1 cecal, 2 ascending colon, 3 transverse colon, 2 sigmoid colon, and 2 rectal cancers. No conversion to open surgery was required and no intraoperative complications occurred. We created 12 sets of FDMs, which were placed at a total of 13 sites in abdominal cavities. FDM fluorescence was successfully detected in all cases. Furthermore, FDMs could be detected earlier than the gauze tags at 12 points, and they were detected at the same time at 1 point.

conclusionsAll FDMs facilitated laparoscopic surgery by allowing the surgeon to find the tissue to be dissected, particularly in procedures that required the dissection of lymph nodes around middle colic vessels and mobilization of the splenic flexure. FDMs showed potential for guiding the laparoscopic surgeon to a target anatomical destination. This marker represents a contribution to the evolution of real-time navigation surgery.

Indexed as

ColonColorectal NeoplasmsLaparoscopyAgedColectomyColoring AgentsDissectionFemaleFluorescent DyesHumansIndocyanine GreenMaleMiddle AgedOutcome and Process Assessment, Health CarePilot ProjectsSurgery, Computer-AssistedColoring AgentsFluorescent DyesIndocyanine GreenColorectal cancerIndocyanine greenLaparoscopic surgeryNavigation

Identifiers

PMID30341652
OpenAlexW2896500722

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.