ArticleMedical physics2018
Mobile C-Arm with a CMOS detector: Technical assessment of fluoroscopy and Cone-Beam CT imaging performance.
Article in Medical physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 28 citations in OpenAlex.
- Comparison of Subjective Image Quality of Mobile C-Arms Equipped with a-Si, CMOS or IGZO Flat-Panel Detectors for Intraoperative Fluoroscopy.Journal of imaging · 2026Article
- From Materials to Medical Images: Translating Perovskite-Based X-Ray Detectors Toward Clinical Imaging.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Review
- Digital Tomosynthesis: Review of Current Literature and Its Impact on Diagnostic Bronchoscopy.Diagnostics (Basel, Switzerland) · 2023Review
- Photon counting-energy integrating hybrid flat panel detector systems for image-guided interventions: an experimental proof-of-concept.Physics in medicine and biology · 2023Article
- A C-arm photon counting CT prototype with volumetric coverage using multi-sweep step-and-shoot acquisitions.Physics in medicine and biology · 2022Article
- Quality assurance and long-term stability of a novel 3-in-1 X-ray system for brachytherapy.Journal of applied clinical medical physics · 2022Article
- Characterization of Flexible Amorphous Silicon Thin-Film Transistor-Based Detectors with Positive-Intrinsic-Negative Diode in Radiography.Diagnostics (Basel, Switzerland) · 2022Article
- Technical assessment of 2D and 3D imaging performance of an IGZO-based flat-panel X-ray detector.Medical physics · 2022Article
- Technical evaluation of the cone-beam computed tomography imaging performance of a novel, mobile, gantry-based X-ray system for brachytherapy.Journal of applied clinical medical physics · 2022Article
- Single-pass metal artifact reduction using a dual-layer flat panel detector.Medical physics · 2021Article
- Characterization and potential applications of a dual-layer flat-panel detector.Medical physics · 2020Article
- A mobile isocentric C-arm for intraoperative cone-beam CT: Technical assessment of dose and 3D imaging performance.Medical physics · 2020Article
- Evaluation of image quality and task performance for a mobile C-arm with a complementary metal-oxide semiconductor detector.Journal of medical imaging (Bellingham, Wash.) · 2020Article
- Comparison of CsI:Tl and GdMedical physics · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 3 institutions in 2 countries.
Funding
Abstract
purposeIndirect-detection CMOS flat-panel detectors (FPDs) offer fine pixel pitch, fast readout, and low electronic noise in comparison to current a-Si:H FPDs. This work investigates the extent to which these potential advantages affect imaging performance in mobile C-arm fluoroscopy and cone-beam CT (CBCT).
methodsFPDs based on CMOS (Xineos 3030HS, 0.151 mm pixel pitch) or a-Si:H (PaxScan 3030X, 0.194 mm pixel pitch) sensors were outfitted on equivalent mobile C-arms for fluoroscopy and CBCT. Technical assessment of 2D and 3D imaging performance included measurement of electronic noise, gain, lag, modulation transfer function (MTF), noise-power spectrum (NPS), detective quantum efficiency (DQE), and noise-equivalent quanta (NEQ) in fluoroscopy (with entrance air kerma ranging 5-800 nGy per frame) and cone-beam CT (with weighted CT dose index, CTDI
resultsThe CMOS FPD exhibited ~2-3× lower electronic noise and ~7× lower image lag than the a-Si:H FPD. The 2D (projection) DQE was superior for CMOS at ≤50 nGy per frame, especially at high spatial frequencies (~2% improvement at 0.5 mm
conclusionMeasurements of image noise, spatial resolution, DQE, and NEQ indicate improved low-dose performance for the CMOS-based system, particularly at lower doses and higher spatial frequencies. Assessment in realistic imaging scenarios confirmed improved visibility of fine details in low-dose fluoroscopy and CBCT. The results quantitate the extent to which CMOS detectors improve mobile C-arm imaging performance, especially in 2D and 3D imaging scenarios involving high-resolution tasks and low-dose conditions.