ArticleEar and hearing
Intracochlear Electrocochleography: Response Patterns During Cochlear Implantation and Hearing Preservation.
Article in Ear and hearing. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06268340 (Preservation of Hearing and Structure Using an Electrocochleography Based Corrective Action Guide), which is not on this map. Cited by 43 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Preservation of Hearing and Structure Using an Electrocochleography Based Corrective Action Guide
Who cites it
43 citing papers in PubMed, 2 syntheses or guidelines pooled it, 98 citations in OpenAlex.
- Pooled it
- Electrocochleography in Cochlear Implant Users with Residual Acoustic Hearing: A Systematic Review.International journal of environmental research and public health · 2020Pooled it
- Multi-Frequency Electrocochleography Results in Fewer Drop Alarms During Cochlear Implant Insertion.The Laryngoscope · 2026Article
- Evaluating Human Auditory Nerve (AN) and Brainstem Function Through Level-Dependent Chirps and Predicted AN Firing Distributions.Journal of the Association for Research in Otolaryngology : JARO · 2026Article
- Monitoring the Cochlea with Intracochlear Electrocochleography During Cochlear Implantation in Pediatric Patients: Setup, Electrocochleography Patterns and Intraoperative Findings.Journal of clinical medicine · 2026Article
- Comparing Slim Straight and Slim Perimodiolar Electrode Arrays for Cochlear Implantation: Hearing Results and Risks-A Systematic Review (2015-2025).Audiology research · 2026Review
- Revealing intracochlear microtrauma during cochlear implantation using optical coherence tomography and electrochemical sensing.Scientific reports · 2025Article
- Impact of Cochlear Trauma Degree and Localization on Intracochlear Electrocochleographic Recordings.Audiology research · 2025Article
- Amplitude and Phase Changes in Electrocochleographic Real-Time Recordings During Cochlear Implantation and Its Relation to Pre- and Postoperative Hearing.Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2025Article
- Validating an Evoked Potential Platform for Electrocochleography During Cochlear Implantation.The Laryngoscope · 2025Article
- Electrical Bioimpedance-Based Monitoring of Intracochlear Tissue Changes After Cochlear Implantation.Sensors (Basel, Switzerland) · 2024Article
- ZH-ECochG Bode Plot: A Novel Approach to Visualize Electrocochleographic Data in Cochlear Implant Users.Journal of clinical medicine · 2024Article
- Two different methods to digitally visualize continuous electrocochleography potentials during cochlear implantation: a first description of feasibility.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2024Article
- Identifying Slim Modiolar Electrode Tip Fold-Over With Intracochlear Electrocochleography.Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2024Article
- Does the audiogram shape influence the intracochlear recording of Electrocochleography during and after cochlear implantation?Frontiers in neuroscience · 2024Article
- Optical method to preserve residual hearing in patients receiving a cochlear implant.Frontiers in audiology and otology · 2024Article
- A frequency peak at 3.1 kHz obtained from the spectral analysis of the cochlear implant electrocochleography noise.PloS one · 2024Article
- Evaluation of Real-Time Intracochlear Electrocochleography for Guiding Cochlear Implant Electrode Array Position.Journal of clinical medicine · 2023Article
- Multi-Frequency Electrocochleography and Electrode Scan to Identify Electrode Insertion Trauma during Cochlear Implantation.Brain sciences · 2023Article
- Cochlear Health and Cochlear-implant Function.Journal of the Association for Research in Otolaryngology : JARO · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
Abstract
objectivesElectrocochleography (ECochG) obtained through a cochlear implant (CI) is increasingly being tested as an intraoperative monitor during implantation with the goal of reducing surgical trauma. Reducing trauma should aid in preserving residual hearing and improve speech perception overall. The purpose of this study was to characterize intracochlear ECochG responses throughout insertion in a range of array types and, when applicable, relate these measures to hearing preservation. The ECochG signal in cochlear implant subjects is complex, consisting of hair cell and neural generators with differing distributions depending on the etiology and history of hearing loss. Consequently, a focus was to observe and characterize response changes as an electrode advances.
designIn 36 human subjects, responses to 90 dB nHL tone bursts were recorded both at the round window (RW) and then through the apical contact of the CI as the array advanced into the cochlea. The specific setup used a sterile clip in the surgical field, attached to the ground of the implant with a software-controlled short to the apical contact. The end of the clip was then connected to standard audiometric recording equipment. The stimuli were 500 Hz tone bursts at 90 dB nHL. Audiometry for cases with intended hearing preservation (12/36 subjects) was correlated with intraoperative recordings.
resultsSuccessful intracochlear recordings were obtained in 28 subjects. For the eight unsuccessful cases, the clip introduced excessive line noise, which saturated the amplifier. Among the successful subjects, the initial intracochlear response was a median 5.8 dB larger than the response at the RW. Throughout insertion, modiolar arrays showed median response drops after stylet removal while in lateral wall arrays the maximal median response magnitude was typically at the deepest insertion depth. Four main patterns of response magnitude were seen: increases > 5 dB (12/28), steady responses within 5 dB (4/28), drops > 5 dB (from the initial response) at shallow insertion depths (< 15 mm deep, 7/28), or drops > 5 dB occurring at deeper depths (5/28). Hearing preservation, defined as < 80 dB threshold at 250 Hz, was successful in 9/12 subjects. In these subjects, an intracochlear loss of response magnitude afforded a prediction model with poor sensitivity and specificity, which improved when phase, latency, and proportion of neural components was considered. The change in hearing thresholds across cases was significantly correlated with various measures of the absolute magnitudes of response, including RW response, starting response, maximal response, and final responses (p's < 0.05, minimum of 0.0001 for the maximal response, r's > 0.57, maximum of 0.80 for the maximal response).
conclusionsMonitoring the cochlea with intracochlear ECochG during cochlear implantation is feasible, and patterns of response vary by device type. Changes in magnitude alone did not account for hearing preservation rates, but considerations of phase, latency, and neural contribution can help to interpret the changes seen and improve sensitivity and specificity. The correlation between the absolute magnitude obtained either before or during insertion of the ECochG and the hearing threshold changes suggest that cochlear health, which varies by subject, plays an important role.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.