Evidence map›Paper›PMID 30328496›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2019

Effect of polyethylene conformity on total knee arthroplasty early clinical outcomes.

Pier Francesco Indelli, Salvatore Risitano, Kimberly E Hall, Erika Leonardi, Eleonora Migliore

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed, 2 pooled it
4.7field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed, 2 syntheses or guidelines pooled it, 39 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Trial
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Review
  15. Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Pier Francesco IndelliDepartment Orthopaedic Surgery and Bioengineering, Stanford University School of Medicine, Stanford, USA. pindelli@stanford.edu.ORCID http://orcid.org/0000-0002-4752-8027
Salvatore RisitanoDepartment Orthopaedic Surgery and Bioengineering, Stanford University School of Medicine, Stanford, USA.
Kimberly E HallDepartment Orthopaedic Surgery and Bioengineering, Stanford University School of Medicine, Stanford, USA.
Erika LeonardiDepartment Orthopaedic Surgery and Bioengineering, Stanford University School of Medicine, Stanford, USA.
Eleonora MiglioreDepartment Orthopaedic Surgery and Bioengineering, Stanford University School of Medicine, Stanford, USA.
VA Palo Alto Health Care System · USAmarillo VA Health Care System · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTotal knee arthroplasty is a successful procedure in treating subjects with end-stage knee osteoarthritis. The objective of this matched study was to evaluate subjective patient satisfaction and clinical and radiological outcomes in two groups of patients undergoing primary TKA using an identical third-generation design with different conformity in the polyethylene insert.

methodsOne hundred consecutive patients undergoing TKA because of knee osteoarthritis were randomized in two matched groups. Group A included 50 Posterior-Stabilized (PS) implants, while group B included 50 Medially Congruent (MC) implants. The surgical technique was identical: gap balancing in extension and measured resection in flexion; cruciate ligaments were always removed; the coronal alignment followed the mechanical axis and the tibial slope was set at 3° in the PS group and 5° in the MC. Oxford Knee Score (OKS) and Knee Society Score (KSS) were assessed preoperatively and at 2 year minimum follow-up. Two-sample T test statistical analysis was performed.

resultsAll patients were available at final follow-up: there were no preoperative statistical differences between the two groups in the average preoperative ROM (PS 112°, MC 108°; n.s.), average preoperative KSS (PS 64.4, MC 63.7; n.s.), average preoperative OKS (PS 19.6; MC 19.0; n.s.), and average BMI (PS 34.40, MC 34.60; n.s.). At final follow-up, there were no statistical differences between the two groups in the average OKS (PS 40,5; MC 41.1; n.s.) and in the average KSS (PS 161,5, MC 165,7; n.s.). We found a statistically but not clinically significant difference at final ROM: the average maximum active flexion was 120° in the PS group and 123° in the MC group (s.s.).

conclusionThis study evaluated two biomechanically different polyethylene inserts in the same TKA design, showing that reducing the level of intra-articular conformity had minimal effects on PROMs and objective short-term clinical results but a potentially beneficial effect on ROM. This study suggests that, once a satisfactory intra-operative stability is obtained, the minimal level of constraint should be used. LEVEL OF EVIDENCE: III.

Indexed as

Knee ProsthesisPatient SatisfactionPolyethyleneAgedAged, 80 and overArthroplasty, Replacement, KneeFemaleHumansKnee JointMaleMiddle AgedOsteoarthritis, KneeProsthesis DesignRange of Motion, ArticularTreatment OutcomePolyethyleneGap balancingKneeMCMedial pivotPolyethyleneResultsTKATotal knee arthroplasty

Identifiers

PMID30328496
OpenAlexW2896839320

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.