Effect of iterative reconstruction and temporal averaging on contour sharpness in dynamic myocardial CT perfusion: Sub-analysis of the prospective 4D CT perfusion pilot study.

Sarah Feger, Carsten Kendziorra, Steffen Lukas, Ahmed Shaban, Björn Bokelmann, Elke Zimmermann, Matthias Rief, Marc Dewey

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Observational
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Sarah FegerDepartment of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany.ORCID 0000-0002-1724-754X
Carsten KendziorraDepartment of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany.
Steffen LukasDepartment of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany.ORCID 0000-0002-2177-6225
Ahmed ShabanDepartment of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany.
Björn BokelmannDepartment of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany.ORCID 0000-0001-9049-2755
Elke ZimmermannDepartment of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany.
Matthias RiefDepartment of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany.
Marc DeweyDepartment of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany.
Charité - Universitätsmedizin Berlin · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeMyocardial computed tomography perfusion (CTP) allows the assessment of the functional relevance of coronary artery stenosis. This study investigates to what extent the contour sharpness of sequences acquired by dynamic myocardial CTP is influenced by the following noise reduction methods: temporal averaging and adaptive iterative dose reduction 3D (AIDR 3D). MATERIALS AND

methodsDynamic myocardial CT perfusion was conducted in 29 patients at a dose level of 9.5±2.0 mSv and was reconstructed with both filtered back projection (FBP) and strong levels of AIDR 3D. Temporal averaging to reduce noise was performed as a post-processing step by combining two, three, four, six and eight original consecutive 3D datasets. We evaluated the contour sharpness at four distinct edges of the left-ventricular myocardium based on two different approaches: the distance between 25% and 75% of the maximal grey value (d) and the slope in the contour (m).

resultsIterative reconstruction reduced contour sharpness: both measures of contour sharpness performed better for FBP than for AIDR 3D (d = 1.7±0.4 mm versus 2.0±0.5 mm, p>0.059 at all edges; m = 255.9±123.9 HU/mm versus 160.6±123.5 HU/mm; p<0.023 for all edges). Increasing levels of temporal averaging degraded contour sharpness. When FBP reconstruction was applied, contour sharpness was best without temporal averaging (d = 1.7±0.4 mm, m = 255.9±123.9 HU/mm) and poorest for the strongest levels of temporal averaging (d = 2.1±0.3 mm, m = 142.2±104.9 HU/mm; comparison between lowest and highest temporal averaging level: for d p>0.052 at all edges and for m p<0.001 at all edges).

conclusionThe use of both temporal averaging and iterative reconstruction degrades objective contour sharpness parameters of dynamic myocardial CTP. Thus, further advances in image processing are needed to optimise contour sharpness of 4D myocardial CTP.

Indexed as

AlgorithmsFour-Dimensional Computed TomographyImage Processing, Computer-AssistedPerfusionFemaleHumansMaleMiddle AgedMyocardiumPilot ProjectsProspective StudiesTime Factors

Identifiers

PMID30325969
PMCPMC6191149
OpenAlexW2897145181

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.