The effectiveness of additional lead-shielding drape and low pulse rate fluoroscopy in protecting staff from scatter radiation during cardiac resynchronization therapy (CRT).
Article in Japanese journal of radiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Equine Standing Multidetector Computed Tomography of the Distal Thoracic Limb and Tarsus Has a Lower Cumulative Radiation Dose than Digital Radiography.Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association · 2025Article
- Radiation dose to the eye of physicians during radio frequency catheter ablation: a small-scale study.Irish journal of medical science · 2024Review
- Occupational radiation exposure among medical personnel in university and general hospitals in Japan.Japanese journal of radiology · 2024Article
- Spatial Scattering Radiation to the Radiological Technologist during Medical Mobile Radiography.Bioengineering (Basel, Switzerland) · 2023Article
- Evaluation of a New Real-Time Dosimeter Sensor for Interventional Radiology Staff.Sensors (Basel, Switzerland) · 2023Article
- Awareness of Medical Radiologic Technologists of Ionizing Radiation and Radiation Protection.International journal of environmental research and public health · 2022Article
- New Radioprotective Device that can be Used for Fluoroscopic Exam: Possibility to Contribute to Staff Exposure Protection During VFSS.Dysphagia · 2022Article
- Development of a New Radiation Shield for the Face and Neck of IVR Physicians.Bioengineering (Basel, Switzerland) · 2022Article
- Non-Lead Protective Aprons for the Protection of Interventional Radiology Physicians from Radiation Exposure in Clinical Settings: An Initial Study.Diagnostics (Basel, Switzerland) · 2021Article
- Evaluation of novel X-ray protective eyewear in reducing the eye dose to interventional radiology physicians.Journal of radiation research · 2021Article
- Double-layered fiber for lightweight flexible clothing providing shielding from low-dose natural radiation.Scientific reports · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeCardiac resynchronization therapy (CRT) often requires a long fluoroscopic time and protection from scatter radiation. This study reports on scatter radiation levels during CRT, with and without additional shielding, and using standard or low pulse rate fluoroscopy. MATERIALS AND
methodsAdditional lead-shielding drape (0.35-mm lead equivalent) was used on the left side of the table and pulsed fluoroscopy was performed at rates of 10 pulses/s (usual rate) and 7.5 pulses/s (low pulse rate). Fluoroscopy scatter radiation was measured for both pulse rates using an acrylic phantom with a radiation survey meter, both with and without the additional lead-shielding drape.
resultsWith the additional lead-shielding drape, the fluoroscopy scatter radiation was reduced by 74.3% at 10 pulses/s and 78.6% at 7.5 pulses/s. If the fluoroscopy was changed from 10 pulses/s to 7.5 pulses/s, the scattered radiation at the primary physician's position was reduced by 24.0%. The combined use of additional shielding drape and low pulse rate fluoroscopy reduced scatter radiation by over 80%.
conclusionAdditional lead-shielding drape and low pulse rate fluoroscopy are effective in reducing the scattered radiation dose to physicians and nurses during CRT.