Evidence map›Paper›PMID 30324227›Full record

ArticleImmunologic research2018

Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform.

Mepur H Ravindranath, Edward J Filippone, Grace Mahowald, Carly Callender, Adarsh Babu, Susan Saidman, Soldano Ferrone

Open access · hybridAbstract read
In one paragraph

Article in Immunologic research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 17 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 2 countries.

Mepur H RavindranathTerasaki Research Institute, Los Angeles, CA, 90064, USA. thiruranganath04@gmail.com.ORCID 0000-0002-5731-4129
Edward J FilipponeDivision of Nephrology, Department of Medicine, Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, PA, USA.
Grace MahowaldDepartment of Pathology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
Carly CallenderImmucor Inc., 3130 Gateway Dr, Norcross, GA, USA.
Adarsh BabuCSRL, University Hospitals Coventry and Warwickshire, Clifford Bridge Road, Coventry, UK.
Susan SaidmanDepartment of Pathology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
Soldano FerroneDepartment of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
Harvard University · USImmucor (United States) · USTerasaki Foundation · USThomas Jefferson University · USUniversity Hospitals Coventry and Warwickshire NHS Trust · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The accurate measurement of anti-HLA alloantibodies in transplant candidates is required for determining the degree of sensitization and for the listing of unacceptable antigens for organ allocation. Both the configuration of the HLA molecules coated on the beads and the nature of detection antibodies may impede assessment of the presence and strength of anti-HLA IgG- with the Luminex single-antigen-bead assay. Sera antibodies of the end-stage renal disease patients were compared using LIFECODES (LC) and LABScreen (LS) beadsets monitored with polyclonal-Fab (IgHPolyFab) and monoclonal-IgG (FcMonoIgG) second antibodies. Positive results at mean fluorescence intensity (MFI) > 500 (at serum dilution 1/10) were used to calculate panel reactive antibody (cPRA) levels. LS-beadsets are coated with monomeric variants in addition to intact HLA antigens with or without peptides, while LC-beadsets are devoid of monomeric variants and with lesser levels of peptide-free heterodimers. Consequently, IgG antibodies against both classes of HLA were reactive to more antigens with LS than with LC-beadsets. For both classes, MFIs were also frequently higher with LS than with LC. For HLA-I, MFIs were higher with IgHPolyFab than with FcMonoIgG with the exception of sera with MFIs > 5000 where they were comparable. For HLA-II, the reverse occurred, with significantly higher levels with FcMonoIgG regardless of the beadsets. The intraindividual variability observed between beadsets with two detection antibodies elucidates that antigens found as acceptable with one beadset may end up unacceptable with the other beadsets, with the possibility of denying potentially compatible transplants to candidates.

Indexed as

Kidney TransplantationAntibodiesEpitope MappingHistocompatibilityHLA AntigensHumansImmunoglobulin GIsoantibodiesObserver VariationRenal Insufficiency, ChronicAntibodiesHLA AntigensImmunoglobulin GIsoantibodiesCalculated panel reactive antibody (cPRA)Denatured antigenFcMonoIgGHeavy chainHuman leukocyte antigenIgHPolyFab: MFI: mean fluorescent intensity (MFI)Single antigen bead assays (SAB)β2-microglobulin

Identifiers

PMID30324227
PMCPMC6244961
OpenAlexW2897708460

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.