ArticleInternational journal of radiation oncology, biology, physics2019
A Spatiotemporal-Constrained Sorting Method for Motion-Robust 4D-MRI: A Feasibility Study.
Article in International journal of radiation oncology, biology, physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 7 citations in OpenAlex.
- View-sharing for 4D magnetic resonance imaging with randomized projection-encoding enables improvements of respiratory motion imaging for treatment planning in abdominothoracic radiotherapy.Physics and imaging in radiation oncology · 2023Article
- Slice-stacking T2-weighted MRI for fast determination of internal target volume for liver tumor.Quantitative imaging in medicine and surgery · 2021Article
- Motion robust 4D-MRI sorting based on anatomic feature matching: A digital phantom simulation study.Radiation medicine and protection · 2020Article
- Respiratory-Correlated (RC) vs. Time-Resolved (TR) Four-Dimensional Magnetic Resonance Imaging (4DMRI) for Radiotherapy of Thoracic and Abdominal Cancer.Frontiers in oncology · 2019Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 2 countries.
Funding
Abstract
purposeTo develop a spatiotemporal-constrained sorting technique for motion-robust 4 dimensional-magnetic resonance imaging. METHODS AND MATERIALS: This sorting method implemented 2 new approaches for 4-dimensional imaging: (1) an optimized sparse k-space acquisition trajectory with self-gating signal derivation, and (2) a retrospective k-space sorting for reconstruction using a novel spatiotemporal-constrained strategy to minimize breathing variation-induced motion artifacts. Such sorting was regularized by a spatiotemporal index. Volumetric reconstruction was implemented iteratively with a secnd-order total generalized variation penalty. The proposed method was evaluated and compared with the conventional phase-sorting and amplitude-sorting methods in 2 studies. In a computer simulation study, 6 abdominal motion scenarios, including 2 cosine and 4 patient breathing motion patterns, were studied. Reconstruction accuracy was evaluated quantitatively in reference to the ground truth by average image relative error (IRE) in 10 phases and target Dice similarity coefficients (DSCs) in end-of-exhalation/inhalation phases. In addition, the proposed method was evaluated using a custom-made motion phantom. Reconstruction accuracy was evaluated by motion range measurement and image quality comparison in both fast and slow breathing motions.
resultsIn the simulation study, stitching motion artifacts in restricted images were lessened using the proposed method compared with those using the conventional methods. The average IRE and target DSC (end-of-exhalation/inhalation) were 0.031 and 0.95/0.94, respectively, suggesting better motion reconstruction accuracy than the phase-sorted method (IRE, 0.057; DSC, 0.89/0.89) and the amplitude-sorted method (IRE, 0.048; DSC, 0.91/0.88). In the phantom study, the moving target reconstructed by the proposed method demonstrated better rendering with less edge blurring. With fast breathing motion, the range measured using the proposed method was more accurate than that of the phase-sorted method and was comparable to the result of amplitude-sorted method and ground truths.
conclusionsPreliminary results suggested that the proposed sorting technique could reconstruct high-quality images and accurate motion estimation with reduced artifacts in 4 dimensional-magnetic resonance imaging.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.