Evidence map›Paper›PMID 30321690›Full record

ArticleInternational journal of radiation oncology, biology, physics2019

A Spatiotemporal-Constrained Sorting Method for Motion-Robust 4D-MRI: A Feasibility Study.

Chunhao Wang, Ergys Subashi, Fang-Fang Yin, Zheng Chang, Jing Cai

Open access · greenAbstract read
In one paragraph

Article in International journal of radiation oncology, biology, physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.1field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 2 countries.

Chunhao WangDepartment of Radiation Oncology, Duke University Medical Center, Durham, North Carolina.
Ergys SubashiDepartment of Radiation Oncology, Duke University Medical Center, Durham, North Carolina.
Fang-Fang YinDepartment of Radiation Oncology, Duke University Medical Center, Durham, North Carolina.
Zheng ChangDepartment of Radiation Oncology, Duke University Medical Center, Durham, North Carolina.
Jing CaiDepartment of Radiation Oncology, Duke University Medical Center, Durham, North Carolina; Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China. Electronic address: jing.cai@polyu.edu.hk.
Duke Medical Center · US

Funding

INTEGRATED CENTER FOR IN VIVO MICROSCOPYP41EB015897 · NIBIB · DUKE UNIVERSITY · PI JOHNSON, GEORGE ALLAN · 2012 to 2017
$7.4M
NIBIB NIH HHS P41 EB015897
6 · The paper itself

Abstract

purposeTo develop a spatiotemporal-constrained sorting technique for motion-robust 4 dimensional-magnetic resonance imaging. METHODS AND MATERIALS: This sorting method implemented 2 new approaches for 4-dimensional imaging: (1) an optimized sparse k-space acquisition trajectory with self-gating signal derivation, and (2) a retrospective k-space sorting for reconstruction using a novel spatiotemporal-constrained strategy to minimize breathing variation-induced motion artifacts. Such sorting was regularized by a spatiotemporal index. Volumetric reconstruction was implemented iteratively with a secnd-order total generalized variation penalty. The proposed method was evaluated and compared with the conventional phase-sorting and amplitude-sorting methods in 2 studies. In a computer simulation study, 6 abdominal motion scenarios, including 2 cosine and 4 patient breathing motion patterns, were studied. Reconstruction accuracy was evaluated quantitatively in reference to the ground truth by average image relative error (IRE) in 10 phases and target Dice similarity coefficients (DSCs) in end-of-exhalation/inhalation phases. In addition, the proposed method was evaluated using a custom-made motion phantom. Reconstruction accuracy was evaluated by motion range measurement and image quality comparison in both fast and slow breathing motions.

resultsIn the simulation study, stitching motion artifacts in restricted images were lessened using the proposed method compared with those using the conventional methods. The average IRE and target DSC (end-of-exhalation/inhalation) were 0.031 and 0.95/0.94, respectively, suggesting better motion reconstruction accuracy than the phase-sorted method (IRE, 0.057; DSC, 0.89/0.89) and the amplitude-sorted method (IRE, 0.048; DSC, 0.91/0.88). In the phantom study, the moving target reconstructed by the proposed method demonstrated better rendering with less edge blurring. With fast breathing motion, the range measured using the proposed method was more accurate than that of the phase-sorted method and was comparable to the result of amplitude-sorted method and ground truths.

conclusionsPreliminary results suggested that the proposed sorting technique could reconstruct high-quality images and accurate motion estimation with reduced artifacts in 4 dimensional-magnetic resonance imaging.

Indexed as

ArtifactsComputer SimulationFeasibility StudiesHumansImage Processing, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance ImagingModels, StatisticalMovementPhantoms, ImagingRespirationRetrospective StudiesSoftwareTime Factors

Identifiers

PMID30321690
PMCPMC12365778
OpenAlexW2897923447

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked