Evidence map›Paper›PMID 30320416›Full record

ArticleJournal of clinical laboratory analysis2019

What makes D-dimer assays suspicious-heterophilic antibodies?

Ying Wu, Ying-Xiu Xiao, Teng-Yi Huang, Xian-Yan Zhang, Huan-Bing Zhou, Xue-Xuan Zhang, Ying-E Wu

Abstract read
In one paragraph

Article in Journal of clinical laboratory analysis, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Disseminated Intravascular Coagulation Score and Sepsis-induced Coagulopathy Score in Prediction of COVID-19 Severity: A Retrospective Analysis.Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2021
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. What makes D-dimer assays suspicious-heterophilic antibodies?Journal of clinical laboratory analysis · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ying WuDepartment of Laboratory Medicine, the First Affiliated Hospital of Shantou University Medical College, Shantou, China.
Ying-Xiu XiaoDepartment of Neurology, the First Affiliated Hospital of Shantou University Medical College, Shantou, China.
Teng-Yi HuangDepartment of Laboratory Medicine, the First Affiliated Hospital of Shantou University Medical College, Shantou, China.
Xian-Yan ZhangDepartment of Laboratory Medicine, the First Affiliated Hospital of Shantou University Medical College, Shantou, China.
Huan-Bing ZhouDepartment of Laboratory Medicine, the First Affiliated Hospital of Shantou University Medical College, Shantou, China.
Xue-Xuan ZhangDepartment of Laboratory Medicine, the First Affiliated Hospital of Shantou University Medical College, Shantou, China.
Ying-E WuDepartment of Laboratory Medicine, the First Affiliated Hospital of Shantou University Medical College, Shantou, China.ORCID http://orcid.org/0000-0001-7135-1391

Funding

Science and Technology Planning Project of Guangdong Province 2014A020212456the National Natural Science Foundation of China 81302540
6 · The paper itself

Abstract

backgroundHeterophilic antibodies are still an important source of interference in immunoassays, but reports of interference with D-dimers are rare. Are D-dimer level abnormalities, found in the clinic, caused by heterophilic antibodies as well, or are other mechanisms involved? We will elaborate on this issue through two different examples in this article.

methodsSerum from two patients with significantly elevated levels of D-dimers were measured and compared by different methods, diluted, and dealt with heterophilic antibody blockers. At the same time, to retrieve the interference, we focused on the cause of D-dimer false positives and made a systematic review of the literature.

resultsThe D-dimer values were normal (0.49 and 0.15 μg/mL) detected with different testing method and decreased after addition of heterophilic antibody blocking reagent. According to literature data, there were 66.7% (4/6) references showed the interference were heterophilic antibody.

conclusionsThe influence of heterophilic antibodies on the measurement of D-dimers remains a big challenge. Different measuring instruments and methods may have significant differences in the measurement of D-dimers. By using a combination of instrumental methods for measuring, incorporating heterophilic antibody blockers, and combining with clinical performance and imaging data, most of the interference can be eliminated.

Indexed as

Fibrin Fibrinogen Degradation ProductsAgedAged, 80 and overAntibodies, HeterophileFemaleHumansImmunoassayReproducibility of ResultsAntibodies, HeterophileFibrin Fibrinogen Degradation Productsfibrin fragment DD-dimerD-dimer assaysHeterophilic antibodyImmunoassayInterference

Identifiers

PMID30320416
PMCPMC6818610

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.