Evidence map›Paper›PMID 30319921›Full record

ArticleBiomedical optics express2018

Constant linear velocity spiral scanning for near video rate 4D OCT ophthalmic and surgical imaging with isotropic transverse sampling.

Oscar M Carrasco-Zevallos, Christian Viehland, Brenton Keller, Ryan P McNabb, Anthony N Kuo, Joseph A Izatt

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 33 papers.

0numbers the graph read from it
0cells of the map it votes in
33citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

33 citing papers in PubMed, 68 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Molecular and cellular imaging of the eye.Biomedical optics express · 2024
    Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Time-Optimal Spiral Trajectories with Closed-Form Solutions.IEEE robotics and automation letters · 2023
    Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Oscar M Carrasco-ZevallosDepartment of Biomedical Engineering, Duke University, Durham, NC 27708 USA.
Christian ViehlandDepartment of Biomedical Engineering, Duke University, Durham, NC 27708 USA.
Brenton KellerDepartment of Biomedical Engineering, Duke University, Durham, NC 27708 USA.
Ryan P McNabbDepartment of Ophthalmology, Duke University Medical Center, NC 27710 USA.
Anthony N KuoDepartment of Biomedical Engineering, Duke University, Durham, NC 27708 USA.
Joseph A IzattDepartment of Biomedical Engineering, Duke University, Durham, NC 27708 USA.
Duke University · USDuke Medical Center · US

Funding

Whole Eye Optical Coherence Tomography to Improve Refractive Surgery and Eye CareR01EY024312 · NEI · DUKE UNIVERSITY · PI KUO, ANTHONY NANLIN · 2015 to 2024
$3.5M
NEI NIH HHS R01 EY024312
6 · The paper itself

Abstract

Ultrahigh speed optical coherence tomography (OCT) systems with >100 kHz A-scan rates can generate volumes rapidly with minimal motion artifacts and are well suited for 4D imaging (volumes through time) applications such as intra-operative imaging. In such systems, high OCT data acquisition efficiency (defined as the fraction of usable A-scans generated during the total acquisition time) is desired to maximize the volumetric frame rate and sampling pitch. However, current methods for beam scanning using non-resonant and resonant mirror scanners can result in severe scan distortion and transverse oversampling as well as require acquisition dead times, which limit the acquisition efficiency and performance of ultrahigh speed 4D OCT. We introduce constant linear velocity spiral scanning (CLV-SC) as a novel beam scanning method to maximize the data acquisition efficiency of ultrahigh speed 4D OCT systems. We demonstrate that CLV-SC does not require acquisition dead times and achieves more uniform transverse sampling compared to raster scanning. To assess its clinical utility, we implement CLV-SC with a 400 kHz OCT system and image the anterior eye and retina of healthy adults at up to 10 volumes per second with isotropic transverse sampling, allowing B-scans with equal sampling pitch to be extracted from arbitrary locations within a single volume. The feasibility of CLV-SC for intra-operative imaging is also demonstrated using a 800 kHz OCT system to image simulated retinal surgery at 15 volumes per second with isotropic transverse sampling, resulting in high quality volume renders that enable clear visualization of surgical instruments and manipulation of tissue.

Identifiers

PMID30319921
PMCPMC6179405
OpenAlexW2893452107

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.