Evidence map›Paper›PMID 30319317›Full record

ArticleSensing and imaging2018

Reduction of Angularly-Varying-Data Truncation in C-Arm CBCT Imaging.

Dan Xia, Yu-Bing Chang, Joe Manak, Adnan H Siddiqui, Zheng Zhang, Buxin Chen, Emil Y Sidky, Xiaochuan Pan

Open access · greenAbstract read
In one paragraph

Article in Sensing and imaging, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Dan XiaDepartment of Radiology, The University of Chicago, Chicago, IL 60637, USA.
Yu-Bing ChangCanon Medical Research Institute USA, Inc., Vernon Hills, IL 60061, USA.
Joe ManakCanon Medical Research Institute USA, Inc., Vernon Hills, IL 60061, USA.
Adnan H SiddiquiUniversity at Buffalo Neurosurgery, Inc., Baffulo, NY 14203, USA.
Zheng ZhangDepartment of Radiology, The University of Chicago, Chicago, IL 60637, USA.
Buxin ChenDepartment of Radiology, The University of Chicago, Chicago, IL 60637, USA.
Emil Y SidkyDepartment of Radiology, The University of Chicago, Chicago, IL 60637, USA.
Xiaochuan PanDepartment of Radiology, The University of Chicago, Chicago, IL 60637, USA.
University of Chicago · USCanon (Japan) · JPUniversity at Buffalo, State University of New York · US

Funding

Digital Specimen Tomosynthesis for Volumetric Imaging of Lumpectomy SpecimensR01EB018102 · NIBIB · UNIVERSITY OF CHICAGO · PI PAN, XIAOCHUAN · 2014 to 2017
$2.0M
Development of Advanced C-arm Cone-Beam CT for the Treatment of Liver CancerR01CA182264 · NCI · UNIVERSITY OF CHICAGO · PI PAN, XIAOCHUAN · 2014 to 2017
$1.8M
Algorithm-Enabled Auto-Calibrating Quantitative Dual-Energy CTR21CA263660 · NCI · UNIVERSITY OF CHICAGO · PI PAN, XIAOCHUAN · 2022 to 2023
$414k
NCI NIH HHS R01 CA182264NCI NIH HHS R21 CA263660NIBIB NIH HHS R01 EB018102
6 · The paper itself

Abstract

C-arm cone-beam computed tomography (CBCT) has been used increasingly as an imaging tool for yielding 3D anatomical information about the subjects in surgical and interventional procedures. In the clinical applications, the limited field-of-view (FOV) of C-arm CBCT can lead to significant data truncation, resulting in image artifacts that can obscure low contrast tumor embedded within soft-tissue background, thus limiting the utility of C-arm CBCT. The truncation issue can become serious as most of the surgical and interventional procedures would involve devices and tubes that are placed outside the FOV of C-arm CBCT and thus can engender angularly-varying-data truncation. Existing methods may not be adequately applicable to dealing with the angularly-varying truncation. In this work, we seek to reduce truncation artifacts by tailoring optimization-based reconstruction directly from truncated data, without performing pre-reconstruction data compensation, collected from physical phantoms and human subjects. The reconstruction problem is formulated as a constrained optimization program in which a data-derivative-ℓ

Indexed as

Angularly-varying-data truncationComputed tomographyData derivativeImage reconstructionOptimization programPrimal-dual algorithm

Identifiers

PMID30319317
PMCPMC6181237
OpenAlexW2802294813

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.