Evidence map›Paper›PMID 30317469›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2019

Modular femoral neck failure after revision of a total hip arthroplasty: a finite element analysis.

Jan Zajc, Jožef Predan, Nenad Gubeljak, Andrej Moličnik, Samo K Fokter

Abstract readCase Reports
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Hyaluronic acid-British anti-Lewisite as a safer chelation therapy for the treatment of arthroplasty-related metallosis.Proceedings of the National Academy of Sciences of the United States of America · 2023
    Article
  6. Review
  7. Article
  8. The Mechanism of Metallosis After Total Hip Arthroplasty.Regenerative engineering and translational medicine · 2021
    Article
  9. Review
  10. Review
  11. Article
  12. Patient-dependent risk factors for self-perceived leg length discrepancy after total hip arthroplasty.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2019
    Observational
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jan ZajcFaculty of Medicine, University of Maribor, Maribor, Slovenia.
Jožef PredanFaculty of Mechanical Engineering, University of Maribor, Maribor, Slovenia.
Nenad GubeljakFaculty of Mechanical Engineering, University of Maribor, Maribor, Slovenia.
Andrej MoličnikDepartment for Orthopaedic Surgery, University Medical Center Maribor, Ljubljanska 5, 2000, Maribor, Slovenia.
Samo K FokterDepartment for Orthopaedic Surgery, University Medical Center Maribor, Ljubljanska 5, 2000, Maribor, Slovenia. samo.fokter@guest.arnes.si.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The authors report on a case of modular femoral neck fracture which appeared 21 months after revision of acetabular component. The revision surgery was performed 8 years after the primary total hip arthroplasty due to aseptic loosening of the acetabular component. During acetabular revision, the primary implanted short (S, - 3.5 mm) femoral head was also exchanged with extra-long (XL, + 7.0 mm) femoral head fitting the modular femoral neck with a longer lever arm. Numerical analysis has shown that this has resulted in a 19.9% increase in tensile stress at the neck-stem coupling during normal walking cycle. This could result in microcrack initiation and propagation and finally lead to modular neck failure of the otherwise well-fixed stem. Surgeons should avoid excessive loading of the exchangeable neck (dual-modular) femoral stem designs as the stem-neck couplings are subject to corrosion and are not as reliable as monoblock stems.

Indexed as

Stress, MechanicalArthroplasty, Replacement, HipFinite Element AnalysisHip ProsthesisHumansMaleMiddle AgedProsthesis FailureReoperationDual-modular stemFinite element modellingModular femoral neck fractureProfemur ZRevision surgeryTotal hip arthroplasty

Identifiers

What OpenQuestion holds

Textmetadata