Evaluation of the effect of image noise on CT perfusion measurements using digital perfusion phantoms.

Stephan Skornitzke, Jessica Hirsch, Hans-Ulrich Kauczor, Wolfram Stiller

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Stephan SkornitzkeDiagnostic & Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany.
Jessica HirschCHRESTOS Institut, Emil-Figge-Straße 43, 44227, Dortmund, Germany.
Hans-Ulrich KauczorDiagnostic & Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany.
Wolfram StillerDiagnostic & Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany. wolfram.stiller@med.uni-heidelberg.de.
Heidelberg University · DEUniversity Hospital Heidelberg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo assess the influence of image noise on computed tomography (CT) perfusion studies, CT perfusion software algorithms were evaluated for susceptibility to image noise and results applied to clinical perfusion studies.

methodsDigital perfusion phantoms were generated using a published deconvolution model to create time-attenuation curves (TACs) for 16 different combinations of blood flow (BF; 30/60/90/120 ml/100 ml/min) and flow extraction product (FEP; 10/20/30/40 ml/100 ml/min) corresponding to values encountered in clinical studies. TACs were distorted with Gaussian noise at 50 different strengths to approximate image noise, performing 200 repetitions for each noise level. A total of 160,000 TACs were evaluated by measuring BF and FEP with CT perfusion software, comparing results for the maximum slope and Patlak models with those obtained with a deconvolution model. To translate results to clinical practice, data of 23 patients from a CT perfusion study were assessed for image noise, and the accuracy of reported CT perfusion measurements was estimated.

resultsPerfusion measurements depend on image noise as means and standard deviations of BF and FEP over repetitions increase with increasing image noise, especially for low BF and FEP values. BF measurements derived by deconvolution show larger standard deviations than those performed with the maximum slope model. Image noise in the evaluated CT perfusion study was 26.46 ± 3.52 HU, indicating possible overestimation of BF by up to 85% in a clinical setting.

conclusionsMeasurements of perfusion parameters depend heavily upon the magnitude of image noise, which has to be taken into account during selection of acquisition parameters and interpretation of results, e.g., as a quantitative imaging biomarker. KEY POINTS: • CT perfusion results depend heavily upon the magnitude of image noise. • Different CT perfusion models react differently to the presence of image noise. • Blood flow may be overestimated by 85% in clinical CT perfusion studies.

Indexed as

AlgorithmsPhantoms, ImagingHumansPerfusion ImagingReproducibility of ResultsTomography, X-Ray ComputedArtifactsPerfusion imagingPhantoms, imagingSoftwareTomography, x-ray computed

Identifiers

PMID30311031
OpenAlexW2897451437

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.