Evidence map›Paper›PMID 30310558›Full record

ArticleJournal of healthcare engineering2018

Mechanical Properties of the Periodontal System and of Dental Constructs Deduced from the Free Response of the Tooth.

Cosmin Sinescu, Virgil-Florin Duma, Dorin Dodenciu, Stefan Stratul, Marius Manole, Gheorghe Eugen Draganescu

Open access · hybridAbstract read
In one paragraph

Article in Journal of healthcare engineering, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 9 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Cosmin SinescuDepartment of Dental Materials and Dental Prostheses Technology, 'Victor Babes' University of Medicine and Pharmacy of Timisoara, 2 Eftimie Murgu Str., 300041 Timisoara, Romania.
Virgil-Florin Duma3OM Optomechatronics Group, Faculty of Engineering, 'Aurel Vlaicu' University of Arad, 77 Revolutiei Ave., Arad 310130, Romania.ORCID 0000-0001-5558-4777
Dorin DodenciuDepartment of Periodontology, 'Victor Babes' University of Medicine and Pharmacy of Timisoara, 2 Eftimie Murgu Str., 300041 Timisoara, Romania.
Stefan StratulDepartment of Periodontology, 'Victor Babes' University of Medicine and Pharmacy of Timisoara, 2 Eftimie Murgu Str., 300041 Timisoara, Romania.ORCID 0000-0002-9154-9511
Marius ManoleDepartment of Dentistry, 'Iuliu Hatieganu' University of Medicine and Pharmacy of Cluj-Napoca, 8 Babes Street, 400012 Cluj-Napoca, Romania.
Gheorghe Eugen DraganescuBioengineering Center, Department of Mechanics and Vibrations, Polytechnic University of Timisoara, 1 Mihai Viteazu Ave., 300222 Timisoara, Romania.
Victor Babeș University of Medicine and Pharmacy Timișoara · ROPolytechnic University of Timişoara · ROIuliu Hațieganu University of Medicine and Pharmacy · RO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The biomechanical behaviour of the periodontal ligament (PDL) is still not well understood although this topic has been studied for almost 100 years. This study reports on clinical and mathematical studies to determine the constitutive law of the PDL. A set of mechanical parameters of the tooth-PDL system is obtained, and a new method for the evaluation of these parameters from the free response of the tooth is introduced. This response is produced by repeated impacts applied to the gingival tissue in the apical part of the tooth investigated-with the aid of a Periotest exciter. A Doppler ultrasound probe is utilized to determine the response of the tooth-PDL system. The parameters evaluated from these measurements can be considered as the elastometric properties of the dental system investigated. A modal analysis/system identification method is utilized to estimate these parameters. The investigations are carried out for different teeth abutments, both with and without a dental bridge/fixed partial prosthesis (FPP). The differences between the responses of the systems in these two cases are determined with the new method proposed. They are discussed with regard to the specific purposes of the FPP. The study demonstrates that this method can provide the dentist with the necessary objective evaluations regarding the properties and health of the tooth-PDL system, as well as of the construct that is obtained after installing a dental bridge.

Indexed as

Biomechanical PhenomenaDental AbutmentsDenture, Partial, FixedHumansModels, BiologicalPeriodontal LigamentSignal Processing, Computer-AssistedToothUltrasonography, Doppler

Identifiers

PMID30310558
PMCPMC6166376
OpenAlexW2890302122

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.