ArticleAJNR. American journal of neuroradiology2018
Optimization of Acquisition and Analysis Methods for Clinical Dynamic Susceptibility Contrast MRI Using a Population-Based Digital Reference Object.
Article in AJNR. American journal of neuroradiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
26 citing papers in PubMed.
- Feasibility of Spin- and Gradient-Echo Dynamic Susceptibility Contrast MRI for Microvascular Characterization at 7 Tesla.NMR in biomedicine · 2026Article
- Exploring the need for a preload on the estimation of permeability, vessel radius, and relative cerebral blood volume in MR vascular fingerprinting-based dynamic susceptibility contrast perfusion imaging.Magnetic resonance in medicine · 2025Article
- Multisite Benchmark Study for Standardized Relative CBV in Untreated Brain Metastases Using the DSC-MRI Consensus Acquisition Protocol.AJNR. American journal of neuroradiology · 2025Article
- "Synthetic" DSC Perfusion MRI with Adjustable Acquisition Parameters in Brain Tumors Using Dynamic Spin-and-Gradient-Echo Echoplanar Imaging.AJNR. American journal of neuroradiology · 2025Article
- The QIBA Profile for Dynamic Susceptibility Contrast MRI Quantitative Imaging Biomarkers for Assessing Gliomas.Radiology · 2024Review
- Identification of a Single-Dose, Low-Flip-Angle-Based CBV Threshold for Fractional Tumor Burden Mapping in Recurrent Glioblastoma.AJNR. American journal of neuroradiology · 2024Article
- Practical guidance to identify and troubleshoot suboptimal DSC-MRI results.Frontiers in radiology · 2024Article
- Integrated molecular and multiparametric MRI mapping of high-grade glioma identifies regional biologic signatures.Nature communications · 2023Article
- Identification of single-dose, dual-echo based CBV threshold for fractional tumor burden mapping in recurrent glioblastoma.Frontiers in oncology · 2023Article
- A cross-sectional study to test equivalence of low- versus intermediate-flip angle dynamic susceptibility contrast MRI measures of relative cerebral blood volume in patients with high-grade gliomas at 1.5 Tesla field strength.Frontiers in oncology · 2023Article
- Voxel-level analysis of normalized DSC-PWI time-intensity curves: a potential generalizable approach and its proof of concept in discriminating glioblastoma and metastasis.European radiology · 2022Article
- Advanced MRI Protocols to Discriminate Glioma From Treatment Effects: State of the Art and Future Directions.Frontiers in radiology · 2022Review
- High-Grade Glioma Treatment Response Monitoring Biomarkers: A Position Statement on the Evidence Supporting the Use of Advanced MRI Techniques in the Clinic, and the Latest Bench-to-Bedside Developments. Part 1: Perfusion and Diffusion Techniques.Frontiers in oncology · 2022Review
- Evaluation of single bolus, dual-echo dynamic susceptibility contrast MRI protocols in brain tumor patients.Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 2021Article
- Validation of combined use of DWI and percentage signal recovery-optimized protocol of DSC-MRI in differentiation of high-grade glioma, metastasis, and lymphoma.Neuroradiology · 2021Article
- Value of dynamic contrast perfusion MRI to predict early response to bevacizumab in newly diagnosed glioblastoma: results from ACRIN 6686 multicenter trial.Neuro-oncology · 2021Article
- Deep-learned time-signal intensity pattern analysis using an autoencoder captures magnetic resonance perfusion heterogeneity for brain tumor differentiation.Scientific reports · 2020Article
- Consensus recommendations for a dynamic susceptibility contrast MRI protocol for use in high-grade gliomas.Neuro-oncology · 2020Article
- Consensus recommendations for a standardized brain tumor imaging protocol for clinical trials in brain metastases.Neuro-oncology · 2020Article
- Evaluating the Use of rCBV as a Tumor Grade and Treatment Response Classifier Across NCI Quantitative Imaging Network Sites: Part II of the DSC-MRI Digital Reference Object (DRO) Challenge.Tomography (Ann Arbor, Mich.) · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
background and purposeThe accuracy of DSC-MR imaging CBV maps in glioblastoma depends on acquisition and analysis protocols. Multisite protocol heterogeneity has challenged standardization initiatives due to the difficulties of in vivo validation. This study sought to compare the accuracy of routinely used protocols using a digital reference object. MATERIALS AND
methodsThe digital reference object consisted of approximately 10,000 simulated voxels recapitulating typical signal heterogeneity encountered in vivo. The influence of acquisition and postprocessing methods on CBV reliability was evaluated across 6912 parameter combinations, including contrast agent dosing schemes, pulse sequence parameters, field strengths, and postprocessing methods. Accuracy and precision were assessed using the concordance correlation coefficient and coefficient of variation.
resultsAcross all parameter space, the optimal protocol included full-dose contrast agent preload and bolus, intermediate (60°) flip angle, 30-ms TE, and postprocessing with a leakage-correction algorithm (concordance correlation coefficient = 0.97, coefficient of variation = 6.6%). Protocols with no preload or fractional dose preload and bolus using these acquisition parameters were generally less robust. However, a protocol with no preload, full-dose bolus, and low (30°) flip angle performed very well (concordance correlation coefficient = 0.93, coefficient of variation = 8.7% at 1.5T and concordance correlation coefficient = 0.92, coefficient of variation = 8.2% at 3T).
conclusionsSchemes with full-dose preload and bolus maximize CBV accuracy and reduce variability, which could enable smaller sample sizes and more reliable detection of CBV changes in clinical trials. When a lower total contrast agent dose is desired, use of a low flip angle, no preload, and full-dose bolus protocol may provide an attractive alternative.