Evidence map›Paper›PMID 30307763›Full record

ArticleComputer assisted surgery (Abingdon, England)2018

Accuracy assessment of a novel image-free handheld robot for Total Knee Arthroplasty in a cadaveric study.

Michael Casper, Riddhit Mitra, Rahul Khare, Branislav Jaramaz, Brian Hamlin, Brian McGinley, David Mayman, Jeff Headrick, Kenneth Urish, Mark Gittins and 2 more

Open access · goldAbstract read
In one paragraph

Article in Computer assisted surgery (Abingdon, England), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed
5.7field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed, 61 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Review
  18. Article
  19. Review
  20. Preliminary experience with an image-free handheld robot for total knee arthroplasty: 77 cases compared with a matched control group.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 7 institutions in 1 country.

Michael Caspera Smith & Nephew Inc. , Pittsburgh , PA , USA.
Riddhit Mitraa Smith & Nephew Inc. , Pittsburgh , PA , USA.
Rahul Kharea Smith & Nephew Inc. , Pittsburgh , PA , USA.ORCID 0000-0003-3820-5194
Branislav Jaramaza Smith & Nephew Inc. , Pittsburgh , PA , USA.ORCID 0000-0002-8602-215X
Brian Hamlinb Department of Orthopaedic Surgery , The Bone and Joint Center, Magee Womens Hospital of the University of Pittsburgh Medical Center , Pittsburgh , PA , USA.
Brian McGinleyc John T. Mather Memorial hospital , Port Jefferson , NY , USA.
David Maymand Orthopaedic Surgery , Hospital for Special Surgery , New York , NY , USA.
Jeff Headricke Orthopedic Surgeon , The Center for Orthopedic Surgery , Lubbock , TX , USA.
Kenneth Urishf Arthritis and Arthroplasty Design Group , The Bone and Joint Center, Magee Womens Hospital of the University of Pittsburgh Medical Center , Pittsburgh , PA , USA.
Mark Gittinsi OrthoNeuro , Cleveland , OH , USA.
Stephen Incavoj Adult Reconstructive Surgery , Houston Methodist Hospital Center for Orthopaedic Surgery , Houston , TX , USA.
Vivek Neginhall Orthopedic Surgeon, Scott Orthopedic Center , Huntington , WV , USA.
Smith & Nephew (United States) · USHospital for Special Surgery · USHouston Methodist · USJohn T. Mather Memorial Hospital · USMagee-Womens Hospital · USOrthopedic Center · USUniversity of Pittsburgh · US

Funding

Biofilm antibiotic tolerance in periprosthetic joint infectionK08AR071494 · NIAMS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI URISH, KENNETH L · 2017 to 2021
$831k
NIAMS NIH HHS K08 AR071494
6 · The paper itself

Abstract

Surgical navigation has been shown to improve the accuracy of bone preparation and limb alignment in total knee arthroplasty (TKA). Previous work has shown the effectiveness of various types of navigation systems. Here, for the first time, we assessed the accuracy of a novel imageless semiautonomous handheld robotic sculpting system in performing bone resection and preparation in TKA using cadaveric specimens. In this study, we compared the planned and final implant placement in 18 cadaveric specimens undergoing TKA using the new tool. Eight surgeons carried out the procedures using three types of implant designs. A quantitative analysis was performed to determine the translational, angular, and rotational differences between the planned and achieved positions of the implants. The mean femoral flexion, varus/valgus, and rotational error was -2.0°, -0.1°, and -0.5°, respectively. The mean tibial posterior slope, and varus/valgus error was -0.2°, and -0.2°, respectively. We obtained higher flexion errors for the femoral implant when using cut-guides as compared to using a bur for cutting the bones. The image-free robotic sculpting tool achieved accurate implementation of the surgical plan with small errors in implant placement. Future studies will focus on determining how well the accurate implant placement translates into a clinical and functional benefit for the patient.

Indexed as

Arthroplasty, Replacement, KneeBone MalalignmentCadaverComputers, HandheldHumansKnee JointKnee ProsthesisReproducibility of ResultsRobotic Surgical Proceduresaccuracycadaver studynavigationrobot-assistedtotal knee arthroplasty

Identifiers

PMID30307763
PMCPMC6309369
OpenAlexW2896411234

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked